The table below presents the different modes of management of the DHW and HC pumps.
ICON
MODE
PUMP
STATUS
OFF
DHW
Closed
HC
Open
SUMMER
DHW
Open
HC
Closed
ON
DHW
Open
HC
Open
PRIORITY*
DHW
Open alternately
DHW: 4’
HC: 45”
HC
*When DHW
≥
60
ο
C, return to ON mode
7.4.2.3.
TIME ZONES mode
The regulator allows you to operate your fireplace with automatic switching between modes
based on certain time zones, using the CLOCK and SPECIAL modes.
!
The regulator time zones are not enabled. Activation and potential adjustment to the parameters must be made in agreement with the
installer and if you understand the way they operate. Any careless changes can cause unstable and inefficient system operation..
7.4.2.4.
SECONDARY CONTROL RELAY mode
The regulator is equipped with a secondary control relay system whose contacts can be
used, for example, to stop the operation of another heat source (e.g. gas boiler) or to
command an additional pump or solenoid when the water temperature reaches a
predetermined value.
7.4.2.5.
TIME ADJUSTMENT screen
The screen displays the current time and the current time zone (when their feature is enabled).To
adjust the hour press the CONFIRM
(
6
) key, so the minutes field start flashing. Press the
(
4
)
ή
(
5
) keys to change the value and the press the TOGGLE
(
7
) key to switch to the time field. After
you finish adjusting the hours field press the CONFIRM
(
6
) button to register the change (the time
field will stop blinking).
7.4.2.6.
PARAMETERS SETTING screen
In the first view of the parameters display there is the definition of "Parameters Level" with the default value "0"
which means that the parameters are not available.
After changing the level to "1", "2", "3" or "4", the following views on the display show the
parameter values in the image on the right. The last screen displays "****" which ends the
definition of the operation parameters, followed by a return to the first screen.
CLOCK
SPECIAL
Relay deactivated(NO)
Relay activated (NC)
Time zone
(if enabled)
Ονοµασία
παραµέτρου
Μονάδα
µέτρησης
Άνω
&
κάτω
όριο
παραµέτρου
Τιµή
παραµέτρου