![ARTE NIREAS Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/arte/nireas/nireas_installation-and-user-manual_2977314015.webp)
I
NSTALLATION
&
USER MANUAL
WATER HEATING FIREPLACE
| NIREAS
14 |
Page
1
Secondary combustion air holes
2
Primary combustion air intake
3
Secondary combustion air intake
4
Lower air curtain
5
Automatic flue damper restore adjustor
6
Upper air curtain
7
Water heating tubes
8
Automated & adjustable flue damper
9
Flue gas baffle
10
Temperature sensor copper tube
11
Water jacket
12
Water jacket insulation
Table 7.2.2
7.3.
General information
7.3.1.
When the fireplace paint dries
ARTE ® products are painted in spray booth with as more environmentally friendly and ecological colors as possible. There is although a
possibility that the first few times the fireplace is lighted, the paint emits an odor. Let the fire burn with intense convection until all traces of
gas disappear and there is no longer a smell. The gas is not toxic, but the room should be well ventilated.
7.3.2.
Incineration preparation
Prepare sufficient amount of chopped firewood, kindling and branches or torches. Before using the wood it is recommended to store them
in a warm place for a few days.
7.3.3.
Combustion air intake
Although the fireplace uses external air for combustion, make sure that the room is ventilated adequately when the fireplace operates
with external fresh air. When you open the door of the combustion chamber for adding firewood there should be no pressure difference
between outdoor and indoor air in the room, so it is good to keep the door open for about 1.5cm for 5-6 seconds and then fully open it.
7.3.4.
Power failure
In case of power failure, the automatic air intake regulator does not stop operating as it is also powered by rechargeable batteries that
allow it to continue its operation for almost 12 hours. So, when the temperature drops to normal levels then the regulator smoothly feeds
back air in the combustion chamber and the operation of the fireplace is continued. However the water pump must also operate. That’s
why it is suggested using an uninterruptible power supply unit (UPS) which will ensure the smooth operation of the pump and therefore the
fireplace.
UNDER NO CIRCUMSTANCE SHOULD YOU OPERATE THE FIREPLACE WITH THE
MAIN DOOR OPEN. YOU RUN A SERIOUS RISK OF DESTROYING THE DEVICE!!!
If you want to import air from an external source, you must apply the corresponding
100mm diameter collar and clamps to mount a flexible conduit.
The air intake must be positioned so as not to allow being covered.
The air intake must be communicating with the combustion space
and protected by a grille.
The minimum surface of the air intake should not be less than
~110cm
2
Avoid using air intakes connected with garages, kitchens,
bathrooms or boiler rooms.