WATER HEATING FIREPLACE
| NIREAS
17 |
Σελίδα
7.4.2.2.
Screens
7.4.2.2.1.
OPERATION screen
It displays the current temperature of the water in the water jacket of the fireplace and the degree of the air damper in percentage. This
screen is fixed and to change it you must press the TOGGLE
(
7
) key.
Water jacket
temperature (
Τ
3)
Current
time
Time zone
(if enabled)
Air intake dumper
opening degree
Set
temperature
Air intake dumper
operation mode
In this screen you can change the temperature in the water jacket of the fireplace. By pressing the CONFIRM
(
6
) key the set temperature
parameter field will start flashing. Press
(
4
) or
(
5
) to change the value and then press the CONFIRM
(
6
) key in order to register the
change.
Also in this screen, when the MANUAL mode is selected and the operation light
(
1
) flashes green, you can manually adjust the position of
the air intake damper position in 10% increments. By pressing the
(
4
) key it opens and by pressing the
(
5
) key it closes.
7.4.2.2.2.
SYSTEM OPERATION screen
Water jacket
temperature (
Τ
3)
DHW pump
status
DHW buffer tank
temperature (T1 & T2)
HC pump
status
Secondary control
relay status
Current
time
Time zone
(if enabled)
DHW pump
operation mode
This screen is fixed and to change it you must press the TOGGLE
(
7
) key.
7.4.2.2.3.
MODE screen
It allows changing the way the fireplace operates and manages the DHW and HC pumps.
The table below presents the different modes of operation of the fireplace.
ICON
MODE
DESCRIPTION
ON
The air intake damper is automatically adjusted in order to stabilize the temperature in the water jacket of the
fireplace. If this mode is selected the operation light
(
1
) illuminates green.
MANUAL
Block automatic control and thus the air intake damper setting and consequently the temperature in the
water jacket of the fireplace is made manually. If this mode is selected the operation light
(
1
) flashes
green.
OFF
The air intake damper remains in the neutral position, i.e. completely closed. If this mode is selected the
operation light
(
1
) is off.
AUTO
Activate the automatic cycle mode Ignition - Operation - Shutdown. If this mode is selected the operation
light
(
1
) illuminates green during the operation of the fireplace and it turns of when it detects shutdown.
AUTO
(start/finish)
This icon appears before the beginning and after the end of AUTO mode.
Press the F1
(
3
) key to activate AUTO mode. The air intake damper opens and light
(
1
) turns on. Within the next 2 hours, the fireplace
should be lit and the water temperature should have reached the specified desired value. From that moment on, a drop in the water
temperature above 10
o
C which is maintained for 30 minutes is treated as a shutdown of the fireplace.
If this occurs, the regulator terminates the cycle by setting the air intake damper to the neutral position (closed). If you press the F1
(
3
) key
again, a new automatic cycle will begin.