WATER HEATING FIREPLACE 

| NIREAS 

 

17 |

 

Σελίδα

 

 

7.4.2.2.

 

Screens 

7.4.2.2.1.

 

OPERATION screen 

It  displays  the current  temperature  of  the  water in  the  water jacket  of  the fireplace  and  the  degree  of  the  air  damper in  percentage.  This 
screen is fixed and to change it you must press the TOGGLE 

 (

7

) key. 

Water jacket

 

temperature (

Τ

3) 

Current 

time 

Time zone 
(if enabled) 

 

Air intake dumper

 

opening degree 

Set 

temperature 

Air intake dumper 
operation mode 

In this screen you can change the temperature in the water jacket of the fireplace. By pressing the CONFIRM 

 (

6

) key the set temperature 

parameter  field  will  start flashing.  Press 

  (

4

)  or 

  (

5

)  to  change  the value  and  then press  the  CONFIRM 

  (

6

)  key in  order  to  register  the 

change. 

Also in this screen, when the MANUAL mode is selected and the operation light 

 (

1

) flashes green, you can manually adjust the position of 

the air intake damper position in 10% increments. By pressing the 

 (

4

) key it opens and by pressing the  

 (

5

) key it closes. 

7.4.2.2.2.

 

SYSTEM OPERATION screen 

Water jacket

 

temperature (

Τ

3) 

DHW pump 

status 

DHW buffer tank 
temperature (T1 & T2) 

HC pump

 

status 

 

Secondary control 
relay status 

Current

 

time 

Time zone 

(if enabled) 

DHW pump 
operation mode 

This screen is fixed and to change it you must press the TOGGLE 

 (

7

) key. 

7.4.2.2.3.

 

MODE screen 

It allows changing the way the fireplace operates and manages the DHW and HC pumps. 

The table below presents the different modes of operation of the fireplace. 

ICON 

MODE 

DESCRIPTION 

 

ON 

The air intake damper is automatically adjusted in order to stabilize the temperature in the water jacket of the 
fireplace. If this mode is selected the operation light 

 (

1

) illuminates green. 

 

MANUAL 

Block  automatic  control  and  thus  the  air  intake  damper  setting  and  consequently  the  temperature  in  the 
water  jacket  of  the  fireplace  is  made  manually.  If  this  mode  is  selected  the  operation  light 

  (

1

)  flashes 

green. 

 

OFF 

The  air  intake  damper  remains  in  the  neutral  position,  i.e.  completely  closed.  If  this  mode  is  selected  the 
operation light 

 (

1

) is off. 

 

AUTO 

Activate  the  automatic  cycle  mode  Ignition  -  Operation  -  Shutdown.  If  this  mode  is  selected  the  operation 
light 

 (

1

) illuminates green during the operation of the fireplace and it turns of when it detects shutdown. 

 

AUTO 

(start/finish) 

This icon appears before the beginning and after the end of AUTO mode. 

Press the F1 

 (

3

) key to activate AUTO mode. The air intake damper opens and light 

 (

1

) turns on. Within the next 2 hours, the fireplace 

should  be  lit  and  the  water  temperature  should  have  reached  the  specified  desired  value.  From  that  moment  on,  a  drop  in  the  water 
temperature above 10 

o

C which is maintained for 30 minutes is treated as a shutdown of the fireplace.  

If this occurs, the regulator terminates the cycle by setting the air intake damper to the neutral position (closed). If you press the F1 

 (

3

) key 

again, a new automatic cycle will begin. 

Содержание NIREAS

Страница 1: ......

Страница 2: ...preparation 14 7 3 3 Combustion air intake 14 7 3 4 Power failure 14 7 3 5 Heating during seasonal change or in adverse weather conditions 15 7 4 Adjusting the combustion air 15 7 4 1 Adjusting the c...

Страница 3: ...ced locally which creates local employment and more tax revenues stay in the province 2 2 Buying firewood Where can I get my firewood Regenerated ready to burn firewood can be purchased from dealers F...

Страница 4: ...rewood Avoid wood that pops chestnut conifers such as cedar spruce and pine as they may damage your fireplace or the flue Pay attention to the size of the logs Good firewood must have been cut at leas...

Страница 5: ...on its insulation In average the required heat output for a properly insulated room and with external temperature of 0 is 40 kCal h per m3 Taking into account that 1kW equals 860 kCal h an equivalent...

Страница 6: ...omising the secure transfer of our products 4 1 Unpacking the fireplace 1 The product will be delivered on a wooden palette which is lined with wooden side panels and top panel Pic 4 1 1 2 Firstly rem...

Страница 7: ...rs Do not use ANY fuel other than the recommended 5 4 Flue security instructions Prior to installing the fireplace ARTE the chimney sweep or a qualified technician should check the condition and opera...

Страница 8: ...e inclination and the distance of the chimney from the ridge according to the following table Pic 5 4 2 3 Inclination RIDGE CHIMNEY DISTANCE MIN HEIGHT ABOVE THE RIDGE m H m 15 1 85 m 0 50 m OVER THE...

Страница 9: ...must be placed on top of the trunk approximately 20cm from the ceiling The grille must always be installed as its purpose is to allow the heat that builds up inside the trunk to be released in the roo...

Страница 10: ...ons referring to national and European standards The installation can be set into operation only after it has been tested by a qualified inspector Prior to installing the new fireplace please contact...

Страница 11: ...d only in case of heater map installation 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE NIREAS fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure...

Страница 12: ...r map installation 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE NIREAS fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure gauge 12 Three way val...

Страница 13: ...ge 12 Three way valve for by pass 5 Drainage 6 Water distribution box 7 Buffer tank 8 Hot water 1 Automatic vent valve 2 Thermometer 3 Overheating safety valve 4 ARTE NIREAS fireplace ARTE NIREAS fire...

Страница 14: ...uipped with the following control systems 7 2 About ARTE NIREAS fireplace The fireplace that you just received is a device designed to offer excellent heating distribution in the area with a very high...

Страница 15: ...ith external fresh air When you open the door of the combustion chamber for adding firewood there should be no pressure difference between outdoor and indoor air in the room so it is good to keep the...

Страница 16: ...r intake damper To prevent overheating they are equipped with a sensor positioned in the copper tube Table 7 2 2 Line 10 of the water jacket where in the case of overheating the device closes the supp...

Страница 17: ...o an outage longer than that an uninterruptible power supply device can be used UPS For safety reasons if the regulator is not receiving power the damper closes completely and is automatically placed...

Страница 18: ...nages the DHW and HC pumps The table below presents the different modes of operation of the fireplace ICON MODE DESCRIPTION ON The air intake damper is automatically adjusted in order to stabilize the...

Страница 19: ...e operation of another heat source e g gas boiler or to command an additional pump or solenoid when the water temperature reaches a predetermined value 7 4 2 5 TIME ADJUSTMENT screen The screen displa...

Страница 20: ...the top of the buffer tank T1 The screen displays WAW temp sensor T1 damaged If the sensor is not installed the alarm is not activated Failure of the sensor on the bottom of the buffer tank T2 The scr...

Страница 21: ...in order for enough air for combustion to enter Close the door again once the wood ignites 7 Ensure there is adequate air supply oxygen to maintain the flame clear and powerful when you reduce the amo...

Страница 22: ...scharged directly through the draft of the flue to the exterior and not in the heating area ARTE NIREAS chamber manages to provide the maximum secondary combustion performance An automatic air intake...

Страница 23: ...be stored in a closed container until cooled down or buried on the ground or dispersed somewhere 10 2 2 Glass ARTE NIREAS fireplace has a single ceramic glass in the window of the combustion chamber i...

Страница 24: ...lean the flue chimney all the way from the fireplace to the flue end point above the house A good practice is to clean the flue after each operating season and to inspect it prior to the start to ensu...

Страница 25: ...ttles inside the fireplace it forms rust which expands the more it settles This can cause excessive pressure on the fireplace joints thus causing damage NOTE It is recommended to thoroughly clean the...

Страница 26: ...WATER HEATING FIREPLACE NIREAS 25 12 DIMENSIONS...

Страница 27: ...Device dimensions W x D x H cm 77 5 50 128 Combustion chamber dimensions W x D x H cm 60 32 42 Flue draft Pa 12 Heated area m2 55 200 Weight kg 208 External air inlet The section must be increased by...

Страница 28: ...artial failure to comply with the specifications contained in it ARTE also declines all responsibility resulting from an improper use of the appliance incorrect use by the user from unauthorized alter...

Страница 29: ...INSTALLATION USER MANUAL WATER HEATING FIREPLACE NIREAS 28 Page NOTES S N S N...

Страница 30: ......

Отзывы: