Chapter VI Application
USER'S MANUAL
6.2 The illumination of multi-function switch in stairs and halls
Control requirements:
1. When pressing switch, illumination is turned on, and automatically turned off
after 3 minutes. Illumination is twinkled 5 seconds before automatically turned
off.
2. Illumination is always turned on after pressing twice in 5 seconds.
3. Illumination is turned off when pressing for 2 seconds and more.
4. Automatically turn on at PM 18:30 and off at AM 6:30 every day.
The program diagram is as below:
Description: I1: connected to the button switch
Q1: connected to the illumination lamp
6.3 Automatic gate control
Control requirements:
1. Opening and closing of the gate shall be controlled by the guard in the control
room.
2. Normally the gate shall be opened or closed completely, but the opening and
closing action can be interrupted at any time.
3. The alarm lamp shall begin to flash when the gate acts and shall keep flashing
as long as the gate continues to move.
4. A pressure damper shall be provided so that the gate can be automatically opened
when it touches a person or an article.
59
Содержание AF-10MR-A2
Страница 1: ......
Страница 11: ...FAB2 Intelligent Controller MEMO 10...
Страница 43: ...FAB2 Intelligent Controller MEMO 42...
Страница 57: ...FAB2 Intelligent Controller 56 MEMO...
Страница 74: ...FAB2 Intelligent Controller MEMO 73 Fig 1 11 The semoval screen of Quick II...
Страница 78: ...FAB2 Intelligent Controller 77 MEMO...
Страница 116: ...FAB2 Intelligent Controller MEMO 115...
Страница 124: ...FAB2 Intelligent Controller MEMO 123...
Страница 126: ...FAB2 Intelligent Controller MEMO 125...
Страница 128: ...FAB2 Intelligent Controller 127...
Страница 129: ......