![Array electronic 3720A Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/array-electronic/3720a/3720a_manual_2975639009.webp)
6
1.6.3
Transient Operation Menu
Press
key in desired mode to enable its transient operation, and press
key to enter
into transient setting menu, which is shown as below:
Function Description
Example
LevelL
Transient low level
1.000A
LevelH
Transient high level
2.000A
TimeL
Time for transient low level
600.00ms
TimeH
Time for transient high level
600.00ms
TimeR
Time for transient rising edge
0.01ms
TimeF
Time for transient falling edge
0.01ms
MODE
Continuous (Cont) Pulse (Puls) Toggle
(Togg)
Cont
Note: Transient operation may be used in CC, CV, and CR modes.
1.6.4
List Operation Menu
Press
key +
key to enter into the list operation menu, which is shown as below:
Function Description
No.
Select sequence (list) number
(
0-6
)
Memo Sequence
memo
(10
characters
)
Data: <New/Edit>
Create a new or edit an existing
sequence
Count
Cycle times
(
1-65535
)
Chain: Off
Sequence number to be
chained with (0-6
,
off)
Press
and
keys in list operation menu to select Data: <New/Edit>, and select New or
Edit with the knob or
and
keys. Then press
key to enter into sequence data editing
status, which is shown as below:
Function Description
01. 10000.00000s
CCH 5.000A
Sequence (List) number
Time
Mode Set value
1.7
Display Messages