27
Fig.2-15 Current Fall Rate
Note: The Curr Fall Rate can be effective only in CCH and CCL mode, and the actual rise rate is
one tenth of the set level in CCL.
2.10
Measurement Function
The electronic load has measurement system with high resolution. The input current level and
voltage level can be measured in real time. The input power level and resistance level can be computed
with the input voltage level and current level. Each measured value can be checked through LCD
display or via the remote command (MEASure:VOLTage?, MEASure:CURRent?,
MEASure:RESistance?, MEASure:POWer?).
2.11 Saving and Recalling
The electronic load is provided with an EEPROM memory, which can save various parameters,
such as modes, input status, current, voltage, resistance, transient settings, limits, etc. 372x Series
electronic load can save 10 groups of parameters. All parameters relevant to saving and recalling
operation are listed in List 2-1 (Take 3721A as an example.).
List 2-1
Function Effect Default
Input Input
status Off
Mode Operation
mode
CCH
Current level
Immediate current level
0A
Current rise rate
Current rise rate
4A/us
Current fall rate
Current fall rate
4A/us
Current Hlevel
Transient current high
level
0A
Current Llevel
Transient current low level
0A
*Current protection level
Current limit
40A
*Current protection delay
Current protection delay
60s
*Current protection State
Enable/disable current
protection
off
Voltage level
Immediate voltage level
80v