28
CV current limit
Current limit in CV mode
40A
Voltage Hlevel
Transient high voltage
level
80v
Voltage Llevel
Transient voltage low level
80v
Resistance level
Immediate resistance level
2000
Ω
Resistance Hlevel
Transient high resistance
high level
2000
Ω
Resistance Llevel
Transient resistance low
level
2000
Ω
Power level
Immediate power level
0W
Transient operation
Transient test
off
Transient mode
Transient mode
continuous
Transient Htime
Time for transient high
level
0ms
Transient Ltime
Time for transient low
level
0ms
Transient Rtime
Time for transient rising
edge
0.01ms
Transient Ftime
Time for transient falling
edge
0.01ms
Trigger Function
Trigger function selection
Tran
*Trigger source
Trigger source
external
Battery Mode
Battery discharge
operation
off
Battery mini voltage
Battery minimum
termination voltage
0V
Battery discharge current
Battery discharge current
0A
Voltage on
Von point for the load
0V
Voltage on Latch
Latch the Von point
Off
* indicates it only can be programmed in the remote control.
The 10 groups of parameters stored in Location 0~9 can be saved and recalled by pressing
key +
key and
key +
key, or via the remote command (*SAV < NRl > and *RCL
< NRl >).
The parameter saved in Location 0 will be recalled automatically every time the load is turned on.
2.12
Reading Remote Programming Errors
The Err annunciator will be turned on when remote programming errors occur. The error codes
are shown as followings:
-lxx Command errors
-2xx Execution errors
-3xx Device-specific errors
-4xx Query errors