![Array electronic 3720A Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/array-electronic/3720a/3720a_manual_2975639058.webp)
55
4.9 Battery Discharge Operation
Battery discharge operation diagram:
The operating procedures for battery discharge operation are shown below:
1.
Press
key to turn off the load, and connect the tested battery correctly.
2.
Press
key +
key to enter into battery discharge operation screen.
3.
Press
key to enter into battery discharge parameters edit screen. Use
,
keys
to select the parameter. Use Entry keys or the knob together with
,
keys to input
termination voltage value and discharge current value. Press
key to confirm.
4.
Press
key to exit the battery discharge parameters edit screen.
5.
Press
key to turn on the load, and start battery discharge operation.
6.
Press
key to turn off the load, and stop battery discharge operation.
7.
Press
key to clear the discharged time and discharged capacity of the battery.
8.
Press
key +
key to exit the battery discharge operation.
Example 1: Enter into the battery discharge operation; set the termination voltage to 15V, and the
discharge current to 3A; turn on the load, and start the battery discharge operation; turn off the load
and stop the battery discharge operation; clear the discharged time and discharged capacity of the
battery; exit the battery discharge operation.
Steps Operation
Descriptions
Display
Step1
Press
key to turn off the load, and connect the tested battery
correctly.
20.000V 0.000A
0.000A CCH OFF
Step2
Press
key +
key to enter into battery discharge
operation screen.
20.000V 0.000A
0.000AH 00:00:00
Step3
Press
key to enter into battery discharge parameters edit
►
MinVolt:0.000V
DisCurr:2.000A