8
④ CP Mode:
The first line shows measured voltage and current levels. The second line shows power set
level, CP mode (CPC indicates constant power-current source mode; CPV indicates constant
power-voltage source mode), and input status of the load: (ON, OFF).
⑤ Transient Operation:
The first line shows measured voltage and current levels. The second line shows set level,
transient operation mode (tCCH indicates high current mode transient operaion; tCCL indicates
low current mode transient operaion; tCV indicates constant voltage mode transient operaion;
tCRL indicates low resistance mode transient operaion; tCRM indicate medium resistance mode
transient operaion and tCRH indicates high resistance mode transient operaion. “t” indicates
transient operation), and input status of the load: (ON, OFF).
⑥ List Operation:
The first line shows measured voltage and current levels. The second line shows set level,
sequence operation mode (
L
CCH indicates high current mode list operaion;
L
CCL indicates low
current mode list operaion;
L
CVindicates constant voltage mode list operation;
L
CRL indicates
low resistance mode list operaion;
L
CRM indicate medium resistance mode list operaion and
L
CRH indicates high resistance mode list operaion. “L” indicates list test; and input status of the
load: (ON, OFF).
⑦ Battery Discharge Operation:
The first line shows measured voltage and current levels. The second line shows battery
capacity and discharge time.