![Aquatec Watermaker AC 110 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/aquatec/watermaker-ac-110/watermaker-ac-110_technical-manual_2961117033.webp)
33
Specification
Pressure regulation valve
Maintenance (only as required) is limited to
cleaning and greasing.
The O-ring (5), (7,5x2 NBR 70), has only to
be changed in case of leakage.
To take the pressure pin out of the valve
body, unscrew the adjusting knob (1). Then
take off the spring (2) with pressure disk (3).
Now you see the pressure (4) pin with a M3
tapped hole, pull it out by screwing in a M3
screw.
Note:
Seal the ¼ “connection thread for
pressure gauges and HP connection with
Loctite 2701.
Hose dimensions
Hose dimensions (inner diameter)
AC 65 / 110
AC 75 up to AC 240
From thru-hull fitting up to feed pump
5/8” / 16 mm
3/4" / 19 mm
From feed pump up to sedimentfilter (20/5mic)
1/2“ / 13 mm
3/4" / 19 mm
From sedimentfilter up to high pressure pump
1/2“ / 13 mm
3/4" / 19 mm
Drain over board (Brine
1/2“ / 13 mm
Fresh water flush
1/2“ / 13 mm
Circulation up to cleaning tank
1/2“ / 13 mm
Circulation from cleaning tank to valve no. 1
1/2“ / 13 mm
3/4" / 19 mm
Product water pipe
3/8“ PE pipe, 1/2“ PVC hose
High pressure hose
¼“
Filter
Sediment filter 5 mic and 20 mic
Cartridge 9 7/8“x 2,5“(251 mm x 65 mm)
Charcoal filter for fresh water flush
Cartridge 9 7/8“x 2,5“(251 mm x 65 mm)