20
Installation guide page 5
Connection concentrate (Brine):
Connect the outlet on the pressure control valve in the control panel to an on-board outlet through a
hose 1/2 "= 13 mm inner diameter.
Warning!
This on-board outlet must be above the waterline and must not be lockable.
The material for the thru-hull must not be made of acetal.
Fresh water pipe
Direct the PE-fresh water pipe from the fresh water outlet at the membrane housing to the inlet at the
flow meter in the control panel.
From the three-way valve (no. 2), direct one pipe to the test-outlet and one pipe from the outlet to the
fresh water tank.
Warning!
Never block the product water line (valve etc.). This damages the membrane
and leads to bursting of the product water line.
EASY TO MAKE A CONNECTION
Cut the tube square and remove burrs and sharp edges.
Ensure the outside diameter is free of score marks.
Push the tube 20 mm into the fitting, up to the tube stop.
To disconnect, ensure the system is depressurized, push the collet
square against the fitting. With the collet held in this position the
tube can be removed.
Attention!
In order to avoid unnecessary back pressure in the product water line, in systems
AC 135 to AC 240 only use the blue 3/8 "product water pipe up to a length of
approx. 5 m.
If necessary, use the supplied adapters from the PE pipe to a 13mm
PVC hose.
Advice
:
A good place for the test-outlet is the sink or basin, where it can be installed by an additional water outlet
without
cut off cock.
At this position, an easy control of the product water is possibly, furthermore you can bottle your drinking
water here directly. This ensures that the quality of the drinking water will be best, since it does not have
to follow a detour over the drinking water tank on-board.
Attention!
If the product water inlet is installed below the tank waterline chlorinated water
(that possibly entered the tank at the last shore water fill up) might flow back
from the tanks into the membranes. As chlorine destroys the R.O. membranes,
a return flow from the tank has to be avoided. A return from the water tank is not
possible if the 3-way valve no. 2 in the control panel is switched to the test outlet
position. A non-return valve must not be used.