background image

AQUASTREAM ULTIMATE

than 1 second) maximum current is 1.5 A. If output current exceeds 1.5 A or 1 A
for a longer period of time, the output will be permanently disabled and a system
alarm (with alarm buzzer) is triggered. To reactivate the output, the aquastream
ULTIMATE (or the complete PC) has to be disconnected from power for a short pe-
riod of time. The fan output is short-circuit proof.
If required, multiple fans can be connected using standard fan splitter cables as
long as the total current does not exceed output specifications.
Pin assignment:

Pin 1: GND
Pin 2: 0-12 V DC output
Pin 3: Speed signal
Pin 4: PWM signal

6.8.

6.8.

6.8.

6.8. Connector for temperature sensor

Connector for temperature sensor

Connector for temperature sensor

Connector for temperature sensor

Connector for a temperature sensor.
Compatible sensors:

Temperature sensor inline G1/4 (53066)

Temperature sensor inner/outer thread G1/4 (53067)

Temperature sensor G1/4 (53147)

Temperature sensor plug&cool (53025)

Temperature sensor 70 cm (53026)

7.

7.

7.

7. Operation of the aquastream ULTIMATE

Operation of the aquastream ULTIMATE

Operation of the aquastream ULTIMATE

Operation of the aquastream ULTIMATE

7.1.

7.1.

7.1.

7.1. Initial operation

Initial operation

Initial operation

Initial operation

Turn off your PC or remove the PSU mains cable if the PSU does not have a power
switch. Remove all cables of the PSU (e. g. from non removable disks, optical stor-
age drives  or  graphic cards).  Take special care to disconnect the 4pin  or 8pin
ATX12V power supply connector from the motherboard as well. Connect the pow-
er connector of the aquastream ULTIMATE to an available SATA power plug of the
power supply unit. 
To   operate   your   aquastream   ULTIMATE   while
filling the system, you have to either start the PC
power supply with the enclosed ATX start plug
or attach  the pump to a second power supply
unit. 
To   start   the   power   supply   unit,   plug   the   ATX
start plug onto the 20pin or 24pin ATX power
supply connector of the PSU. After you have at-
tached the plug to the PSU and turned on the
mains switch of the PSU, the PSU and pump will immediately power up. Proceed
by filling the water cooling system with coolant.

- 8 -

Aqua Computer GmbH & Co. KG

© 2016-2018

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание aquastream ULTIMATE

Страница 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Страница 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Страница 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Страница 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Страница 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Страница 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Страница 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Страница 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Страница 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Страница 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Страница 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Страница 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Страница 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Страница 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Страница 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Страница 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Страница 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Страница 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Страница 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Страница 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Страница 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Страница 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Страница 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Страница 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Страница 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Страница 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Страница 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Страница 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Отзывы: