background image

AQUASTREAM ULTIMATE

cense  is permanently assigned to the  selected device and stored on  the license
server. The key will not have to be re-entered after reinstallation of the software or
transfer of the device to another computer, but transferring the license to another
device is not possible.

During license validation and software activation, device serial numbers and a cal-
culated computer ID are transmitted to and stored on the license server. No further
personal information such as IP addresses are stored.

19.

19.

19.

19. Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting

19.1.

19.1.

19.1.

19.1. Restore factory defaults

Restore factory defaults

Restore factory defaults

Restore factory defaults

There are three options to reset the pump controller to factory defaults. Restoring
factory defaults may be useful if the pump is not properly operating or if erroneous
settings have been saved into the pump. 

1. aquasuite: Click the “Reset device to factory defaults” button on the “Sys-

tem” screen.

2. Device menu: Select “System”, then “Factory defaults” and confirm by press-

ing the middle key.

3. Turn off the PC. Press and hold the middle key and turn on the PC. Release

the key once pump data is displayed. 

19.2.

19.2.

19.2.

19.2. Replacement parts

Replacement parts

Replacement parts

Replacement parts

The following genuine parts can be used with the aquastream ULTIMATE pump:

Description

Description

Description

Description

Aqua Computer part number

Aqua Computer part number

Aqua Computer part number

Aqua Computer part number

Eheim part number

Eheim part number

Eheim part number

Eheim part number

Pump cover

41032

7439909

Gasket for pump cover

92014

7263550

Ceramic axis

41031

7433720

Impeller incl. ceramic axis

41065

Not compatible!

Mounting plate

41036

7264509

Suction grille

41086

7263609

All spare parts can be obtained from Aqua Computer. Eheim spare parts may also
be available from local aquarium supply stores.

20.

20.

20.

20. Technical details and care instructions

Technical details and care instructions

Technical details and care instructions

Technical details and care instructions

20.1.

20.1.

20.1.

20.1. Technical details

Technical details

Technical details

Technical details

Power supply voltage (Vin):

12 V DC ±5 %

Power consumption:

ca. 3 to 25 Watts

© 2016-2018

Aqua Computer GmbH & Co. KG

- 27 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание aquastream ULTIMATE

Страница 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Страница 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Страница 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Страница 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Страница 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Страница 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Страница 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Страница 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Страница 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Страница 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Страница 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Страница 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Страница 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Страница 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Страница 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Страница 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Страница 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Страница 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Страница 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Страница 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Страница 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Страница 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Страница 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Страница 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Страница 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Страница 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Страница 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Страница 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Отзывы: