This   function  can  be   used to add  annotations  to  the  chart.  While  this
function is activated, simply click into the chart to add an annotation at
the current cursor position. By clicking into the text box, you may edit the

text. You may also drag the little circle beside the text box to move the connecting
line to the desired position. Use drag and drop to move existing annotations.

This function can be used to remove horizontal/vertical lines or annota-
tions from the chart. While this function is activated, simply click the ele-
ment to be removed.
This function can be used to move the visible portion of the chart. Press
and hold the mouse button while moving the cursor in the chart to select
the position to be displayed, then release the button.
This function can be used to zoom in and out. Use the mouse wheel or
select the area to be displayed. You can reset the zoom settings by dou-
ble-clicking in the chart area.
This function will completely remove the chart.

10.3.

10.3.

10.3.

10.3. Manual data export

Manual data export

Manual data export

Manual data export

Saved data can be exported from the data log into a XML file. To do so, select
“Analyze   data”   below   the   “Data   log”   headline   in   the   listing.   Select   the   “Data
sources” tab in the chart configuration and select a data set to be exported. If no
data sources are available, you will have to configure the log settings as described
in the chapter “Log settings” of this manual. Select the time period to be exported
on the right side of the window and start the export process by clicking the “Export
data” button. Enter a file name and path in the following dialog window.

10.4.

10.4.

10.4.

10.4. Automatic data export

Automatic data export

Automatic data export

Automatic data export

The automatic data export feature can be used to save data from the aquasuite
into an XML file on the hard disk or in the RAM (“memory mapped file”) in a regu-
lar  time interval.  The automatic data export will always  overwrite the  previously
saved data, so the file always contains only the most recent data set. Select “Auto-
matic data export” below the “Data log” headline in the listing to access the set-
tings screen. Create a new export data set by clicking the plus symbol in the upper
right corner  of the screen. Enter name, path  and time interval to meet your re-
quirements. You may then add the data sources to log by clicking the plus symbol
in the “Data sources” window section. You may add an unlimited number of data
sources to each export data set, the total number of export data sets is also unlim-
ited. 

© 2016-2018

Aqua Computer GmbH & Co. KG

- 15 -

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание aquastream ULTIMATE

Страница 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Страница 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Страница 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Страница 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Страница 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Страница 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Страница 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Страница 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Страница 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Страница 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Страница 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Страница 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Страница 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Страница 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Страница 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Страница 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Страница 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Страница 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Страница 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Страница 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Страница 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Страница 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Страница 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Страница 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Страница 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Страница 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Страница 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Страница 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Отзывы: