In contrast, the “Data log” may be used to selectively and permanently store data
from all connected Aqua Computer devices and hardware data supplied by the
background service. Logged data can then be analyzed by creating charts or be
exported to files. Data is only logged while the aquasuite software is being execut-
ed.

10.1.

10.1.

10.1.

10.1. Log settings

Log settings

Log settings

Log settings

The log settings can be accessed by clicking the “Log settings” element below the
“Data log” headline in the listing. To log data, create a new log data set by click-
ing the plus symbol in the upper right corner of the settings window. Enter name,
time interval and configure automatic deletion of old data to meet your require-
ments. You may then add the data sources to log by clicking the plus symbol in
the “Data sources” window section. You may add an unlimited number of data
sources to each log data set, the total number of log data sets is also unlimited.

10.2.

10.2.

10.2.

10.2. Analyze data

Analyze data

Analyze data

Analyze data

Logged data can be visually evaluated as charts. To do so, select “Analyze data”
below the “Data log” headline in the listing. The chart will initially be empty, di-
rectly below the chart are eight buttons to modify the chart. In the lower section of
the window, the chart data can be configured.
To add data to the chart, first select the “Data sources” tab in the chart configura-
tion and select a data set to be displayed. If no data sources are available, you
will have to configure the log settings as described in the chapter “Log settings” of
this manual. Select the time period to be displayed on the right side of the window
and add the data to the chart by clicking the “Add data to chart” button. Repeat
this procedure if you want to display more than one data set in the chart. 
You may modify the chart using the “Chart setup” and “Data series setup” tabs.
Finally, you can use the “Chart manager” tab to save the current chart configura-
tion and to load or delete previously saved configurations. All saved chart configu-
rations will be available on overview pages for the “Log data chart” element. 
The currently displayed chart can be edited by using the buttons directly below the
chart and may also be saved as an image file. The button corresponding to the
currently selected function is highlighted by an orange frame. Please refer to the
following list for details on each function:

To save the currently displayed chart as  an  image file, click the floppy
disk symbol and select a name and location in the following dialog. 

This function can be used to add horizontal lines to the chart. While this
function is activated, simply click into the chart to add a line at the current
cursor position.
This function  can be used to add vertical lines  to the chart. While  this
function is activated, simply click into the chart to add a line at the current
cursor position.

- 14 -

Aqua Computer GmbH & Co. KG

© 2016-2018

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание aquastream ULTIMATE

Страница 1: ...nd installation manual aquastream ULTIMATE aquasuite version 2018 Current as of October 2018 All information contained in this manual is subject to change without prior notice All rights reserved 2016...

Страница 2: ...n 9 8 aquasuite software 9 8 1 Installation of the aquasuite software 9 8 2 Basic operation 10 8 3 Symbols in the headlines 10 9 Overview pages aquasuite 11 9 1 Desktop mode 11 9 2 Creating new overvi...

Страница 3: ...ensor configuration 21 14 1 External flow sensor 21 14 2 Virtual flow sensor software extension Virtual Flow Sensor only 21 14 3 Offsets for temperature sensors 21 14 4 Software temperature sensors Ad...

Страница 4: ...e to be observed at all times Read this manual thoroughly and entirely Save your data onto suitable media before working on your hardware The pump must not be placed under water The pump controller on...

Страница 5: ...ump 5 5 5 5 Assembly instructions Assembly instructions Assembly instructions Assembly instructions Install connecting adapters not included in delivery to the aquastream ULTIMATE The adapters should...

Страница 6: ...ou are having trouble to connect Pin assignment Pin 1 2 3 7 8 9 11 not connected Pin 4 5 6 10 12 GND Pin 13 14 15 12 V DC 6 3 6 3 6 3 6 3 Connector USB Connector USB Connector USB Connector USB This c...

Страница 7: ...or the switching signal can be activated in case of an alarm condition for configuration see chapter 13 2 For example the aquabus speed signal cable in cluded in delivery can be used to connect this h...

Страница 8: ...on of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE Operation of the aquastream ULTIMATE 7 1 7 1 7 1 7 1 Initial operation Initial operation Initial...

Страница 9: ...isplay the aquasuite software should be closed on a connected PC Otherwise the aquasuite will overwrite and thereby cancel any settings made on the device itself 7 3 7 3 7 3 7 3 Configuration using US...

Страница 10: ...icking the arrow symbol in the upper left corner List elements may be minimized or maximized for easier access by clicking the title bar The title bars may contain various symbols that will be explain...

Страница 11: ...uasuite window for editing and the current desktop will be displayed as background for your convenience 9 2 9 2 9 2 9 2 Creating new overview pages and activating edit mode Creating new overview pages...

Страница 12: ...vailable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chro...

Страница 13: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Страница 14: ...n the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure the log settings as described in the chapter Log settings of this manual Se...

Страница 15: ...Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are available you will have to configure the log settings as described in the chapter Log...

Страница 16: ...eset speed preset If speed preset mode is selected you can manually set the desired rotation speed of the pump If the selected speed cannot be attained the pump controller will use the highest stable...

Страница 17: ...om level for this axis a double click into the diagram will reset both axes Selecting an area on an axis will zoom this axis to this area selecting an area in the diagram will zoom both axes to this a...

Страница 18: ...ent corresponding to the current temperature is scaled to the range between minimum and maximum fan power settings before being ap plied to the fan output The startup temperature will also be factored...

Страница 19: ...tput range can be limited by setting Minimum power and Maximum power values correspondingly The check box Hold minimum power determines whether the fan will be switched off during a power setting of 0...

Страница 20: ...t up but are not active presently are highlighted with a yel low background color Make sure only to use readings for alarm evaluation that are functional with your specific setup 13 4 13 4 13 4 13 4 S...

Страница 21: ...y 10 Flow rates below 40 l h will not be displayed due to increasing imprecision of the calculation method for low flow rates Limitations Flow rate can not be calculated if a second pump is present in...

Страница 22: ...r temperature sensor selection Water temperature sensor selection Select one of the available temperature sensors to be displayed as Water temper ature in the information pages on the pump display Thi...

Страница 23: ...up port You may enter a Device description for easier identification this text will be displayed in the device list and in the data quick view 16 2 16 2 16 2 16 2 Factory defaults Factory defaults Fac...

Страница 24: ...rmware update process the language of the pump menu will auto matically be set to the currently selected language in the aquasuite software To change the language of the pump menu first select the des...

Страница 25: ...m the transmitted data suitable to be included in forums signatures The code required for the Aqua Computer forums is provided for your convenience 17 3 17 3 17 3 17 3 Data import Data import Data imp...

Страница 26: ...lowing annual ver sion For software activation at least one device in the computer must contain a corresponding license If a valid license is detected for at least one device all de vices connected to...

Страница 27: ...ess ing the middle key 3 Turn off the PC Press and hold the middle key and turn on the PC Release the key once pump data is displayed 19 2 19 2 19 2 19 2 Replacement parts Replacement parts Replacemen...

Страница 28: ...his device has to be disposed of as electronic waste Please check your local regulations for disposal of electronic waste 20 4 20 4 20 4 20 4 Contact Aqua Computer Contact Aqua Computer Contact Aqua C...

Отзывы: