- 5 -
Field Function
Programmed Values
[ ] = Table 1 Default Values
✱
42
SECONDARY PHONE NUMBER
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24 digits
entered, pressing
✻
advances to the next field. To clear entries from
field, press
✻
41
✻
.
!
All four digits of the subscriber account number must be entered in Fields
✻
✻
✻
✻
43 and
✻
✻
✻
✻
44.
If ten digit format is
selected in
✻
✻
✻
✻
48 (option 5), all ten digits of the Subscriber Account number must be entered.
For fields
✻
43,
✻
44:
Enter 4 to 10 digits. Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter
✻
as 4th digit, if 3+1
dialer reporting is to be used. If only 3 digits used, pressing
✻
advances to the next field. Enter [
✻
] as the fifth digit if a 4-
digit account number (for 3+1, CID®) is used.
To clear entries from field, press
✻
43
✻
or
✻
44
✻
. Examples:
For Acct.
1234
, enter: 1 | 2 | 3 | 4 ; For Acct.
B234
, enter: #+11| 2 | 3 | 4 For Acct.
1234567890
, enter:
1| 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 0 ; For Acct.
123
, enter: 1 | 2 | 3 |
✻
✱
43
PRIMARY SUBS ACCT #
See note above.
✱
44
SECONDARY SUBS ACCT #
See note above.
For field
✻
46
Enter up to 24 digits. Enter 0-9, #+11 for ‘
✻
’; #+12 for ‘#’; #+13 for a pause (two seconds).
✱
46
“FOLLOW ME” REMINDER
PHONE NUMBER
Enter up to 24 digits; Do not fill unused spaces. If fewer than 24 digits
entered, pressing
✻
advances to the next field. To clear entries from
field, press
✻
46
✻
.
✱
47
PHONE SYSTEM SELECT
† [5]
Central
Dialing Mode
Station
Pulse
Tone
Pulse
Tone
No WATS
0 = No Speaker
Phone
1 = No
Speaker Phone
4 = With
Speaker Phone
5 = With
Speaker Phone
WATS
2 = No Speaker
Phone
3 = No
Speaker Phone
6 = With
Speaker Phone
7 = With
Speaker Phone
✱
48
REPORT FORMAT for PRIM./SEC
[7, 7]
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = ADEMCO CONTACT ID® REPORTING WITH 10-DIGIT SUBS ACCT NO.
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING WITH 4-DIGIT SUBS ACCT NO.
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
† Entering a number other than the one specified may give unpredictable results.
Note:
If you are using Pulse (rotary) Dialing, you must
enter the numbers slowly to allow the pulse dialer
time to operate.
Note:
Option 5 or
7 (ADEMCO Contact ID®)
must be selected for AAV.