- 3 -
TO EXIT PROGRAMMING MODE:
✻
98 Exits programming mode and
prevents
re-entry by: Installer Code + 8+ 0 + 0. If
✻
98 is used to exit
programming mode, system must be powered down, then press [
✻
] and [#] within 50 seconds of power
up to re-enter programming mode.
✻
99 Exits programming mode and
allows
re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press
[
✻
] and [#] within 50 seconds of power up.
DATA FIELDS
Field Function
Programmed Values
[ ] = Table 1 Default Values
SYSTEM SETUP (
✱
20–
✱
30)
✱
20
INSTALLER CODE
[4112]
Enter 4 digits, 0–9
✱
21
QUICK ARM ENABLE
†
[1]
0 = no; 1 = yes
✱
22
KEYPAD BACKLIGHT TIMEOUT
[0]
0 = none (backlighting always on); 1 = backlight off after 10secs
✱
23
FORCED BYPASS
†
[0]
0 = none; 1 = bypass open zones
UL installations = 0
✱
24
RF HOUSE ID CODE
|
[00]
00 = disable all wireless keypad usage;
01–31 = 5804BD/5804BDV house ID
✱
25
POWERLINE CARRIER DEVICE
HOUSE CODE
[0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I,
9 =
J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P
✱
26
CHIME BY ZONE
† [0]
0 = no; 1 = yes (program zones to chime on zone list 3)
✱
27
REAL TIME CLOCK DISPLAY
† [1]
0 = no; 1 = yes, display time on keypad
✱
29
DAYLIGHT SAVING TIME
START/END MONTH
[3, 11]
Start
End
1-9, #+10,#+11,#+12. Enter 0,0 if no daylight savings time used.
✱
30
DAYLIGHT SAVING TIME
START/END WEEKEND
[2,1]
Start End
0=disable; 1=first; 2=second; 3=third; 4=fourth;
5=last; 6=next to last; 7=third from last
ZONE SOUNDS AND TIMING (
✱
✱
✱
✱
31–
✱
✱
✱
✱
39)
✱
31
SINGLE ALARM SOUNDING/ZONE
† [0]
0 = Alarm Sounding Per Zone will be the same as the Swinger
Shutdown” set in field *92;
1 = yes, limit once per arming period (also applies to long range
radio output if “0” is selected in
✻
91 field)
UL installations = 0
† Entering a number other than the one specified may give unpredictable results.