background image

 

 

 

APX32EN 

  

Security 

Systems 

    

    

 

Programming Guide 

 

 
 
 
 

 

 
 
 
 
 

 
 

 

 

K14116-8  11/07  Rev. A

Содержание APX32EN

Страница 1: ...APX32EN Security Systems Programming Guide K14116 8 11 07 Rev A ...

Страница 2: ... be displayed the first data field in the system and both keypad LEDs will flash TO PROGRAM THE DATA FIELDS 1 Press followed by the desired field number e g 21 then make the required entry 2 The keypad beeps three times after entering data then displays the next data field in sequence 3 For phone number and account number fields press to end the entry if less than number maximum number of digits i...

Страница 3: ...0 00 disable all wireless keypad usage 01 31 5804BD 5804BDV house ID 25 POWERLINE CARRIER DEVICE HOUSE CODE 0 0 A 1 B 2 C 3 D 4 E 5 F 6 G 7 H 8 I 9 J 10 K 11 L 12 M 13 N 14 O 15 P 26 CHIME BY ZONE 0 0 no 1 yes program zones to chime on zone list 3 27 REAL TIME CLOCK DISPLAY 1 0 no 1 yes display time on keypad 29 DAYLIGHT SAVING TIME START END MONTH 3 11 Start End 1 9 10 11 12 Enter 0 0 if no dayli...

Страница 4: ...ding after arming system by APX32EN keypad or RF keypad 1 arming confirmation ding after arming system by APX32EN keypad or RF keypad 2 arming confirmation ding after arming from RF keypad only If Option 1 is selected confirmation of arming is provided by a 1 2 second sounder ding that sounds when closing report is sent or at the end of exit delay If Option 2 is selected the external sounder ding ...

Страница 5: ...note above For field 46 Enter up to 24 digits Enter 0 9 11 for 12 for 13 for a pause two seconds 46 FOLLOW ME REMINDER PHONE NUMBER Enter up to 24 digits Do not fill unused spaces If fewer than 24 digits entered pressing advances to the next field To clear entries from field press 46 47 PHONE SYSTEM SELECT 5 Central Dialing Mode Station Pulse Tone Pulse Tone No WATS 0 No Speaker Phone 1 No Speaker...

Страница 6: ... All except Open Close TO SECONDARY FOLLOW ME SYSTEM PHONE No Alarms Open Close Troubles Alarms Troubles Alarms Open Close Troubles Open Close Will report users 0 5 8 or wireless arm disarm button zones 26 33 all other zones and users do not report 50 15 SEC DIALER DELAY BURG 0 0 no 1 yes UL installations 0 51 PERIODIC TEST REPORT 0 0 none 1 24 hours 2 weekly 3 30 days enter Test Code in field 64 ...

Страница 7: ... report Examples For Code 3 single digit enter 3 0 For Code 3 2 two digits enter 3 2 For Code B 2 Hexadecimal enter 11 2 SYSTEM STATUS REPORT CODES 59 68 59 EXIT ERROR REPORT CODE 1 60 TROUBLE REPORT CODE 1 0 61 BYPASS REPORT CODE 0 0 62 AC LOSS REPORT CODE 0 0 63 LOW BATTERY REPORT CODE 1 0 64 TEST REPORT CODE 1 0 65 OPEN REPORT CODE 0 66 ARM AWAY STAY RPT CODE 0 0 AWAY STAY 67 RF XMTR LOW BAT RE...

Страница 8: ...ND SYSTEM SETUP 80 92 80 81 DEVICE PROGRAMMING MENU MODE ZONE LISTS MENU MODE Program 80 and 81 only if Powerline Carrier Devices or chime by zone are to be used See procedure later in this manual 83 ENHANCED SEQUENTIAL MODE See procedure later in this manual 84 ASSIGN ZONE VOICE DESCRIPTOR See procedure later in this manual 85 RECORD CUSTOM VOICE DESCRIPTOR See procedure later in this manual 86 M...

Страница 9: ...lection is made 91 ALARM AUDIO VERIFICATION AAV REMOTE PHONE CONTROL 2 0 None 1 AAV and remote phone control 2 remote phone control only 4 AAV only Notes 1 In order to activate the Remote Phone Control feature and defeat an answering machine ensure that the correct ring detection count 15 has been programmed in field 95 2 Remote phone session will be terminated if a report must be sent 3 Alarm Aud...

Страница 10: ...LIZE DOWNLOAD ID SUBSCRIBER ACCOUNT No entry required 97 SET ALL PROGRAM FIELDS TO DEFAULT VALUES Enter 1 to select default table Enter 0 to abort 98 EXITS PROGRAMMING MODE PREVENTS RE ENTRY If 98 is used to exit programming mode you cannot enter the Installer Code 8 0 0 for re entry You must press and within 50 seconds of power up or from exiting Programming mode to re enter Programming mode Note...

Страница 11: ...RF Learning Two 2 transmissions two key depressions at least five seconds apart will be required for BR type devices device type 5 Two beeps will sound after the second transmission confirming that the loop number and serial number have been learned For all other device types four 4 transmissions are required fault restore and fault restore A single beep will sound after the second transmission co...

Страница 12: ...ey to return to prompt 1A Note In order for all parameters to be accepted you must advance to prompt 1C When all 7 digits are entered press the key The serial number will be copied into EEROM and the local memory buffer and the system will return to the 1A prompt and L will be displayed If 52 seconds pass and no entry is been made the system will return to prompt 1A IC VOICE DESCRIPTOR 0 Skip to n...

Страница 13: ...ay closed Return to previous prompt C et START EVENT TYPE if applicable Enter the 1 digit start event type 0 3 for the device being programmed 0 Not used 3 Trouble 1 Alarm Continue 2 Fault Return to previous prompt d zl START ZONE LIST if applicable Enter the 1 digit zone list number 1 3 or 0 if not used for the device being programmed Continue Return to previous prompt E zt START ZONE TYPE if app...

Страница 14: ... the 2 digit zone number zz to be added to this zone list The system will announce the Voice Descriptor for the selected zone if it is programmed Accept zone number and enter the next zone number 00 Accept zone number and continue to next prompt C DELETE ENTIRE ZONE LIST 0 Don t delete continue to next prompt 1 Delete the current zone list d DELETE SPECIFIC ZONES FROM LIST 0 Don t delete continue ...

Страница 15: ...the 1A prompt For 4 button key zones 26 29 30 33 34 37 and 38 41 deletes all four at once Advance to the next unlearned zone Return to previous prompt 1A Ib zz Ib SERIAL NUMBER This prompt can be used to enroll the transmitter serial number via RF transmission or manually RF Learning Two 2 transmissions two key depressions at least five second apart will be required for BR type or four 4 transmiss...

Страница 16: ...2 digit vocabulary index number of third descriptor word for this zone To change the entered index number press desired index number 6 or 8 accept word and advance to next zone prompt A zz zone descriptor will be announced Press any other key to repeat the selected word VOCABULARY INDEX 00 sec pause A 82 ALARM 32 ATTIC B 01 BABY 33 BACK 34 BASEMENT 35 BATHROOM 36 BEDROOM C 83 CHECK D 37 DELAY DOOR...

Страница 17: ...STOM DESCRIPTOR NUMBER Enter 7 d where d 0 4 each representing custom word 70 71 72 73 or 74 respectively Existing descriptor will be announced Press to start recorder Begin speaking immediately after the third beep Speak the desired word clearly near the keypad microphone Recording stops after 1 5 seconds 6 Accept word and ready to record next descriptor prompt A 7d Re record descriptor 00 Exit R...

Страница 18: ...iption No a 02 Type zt hex rc Index Zone No Zone Alarm Report Input Loop Transmitter Vocabulary A 02 Type zt Code in hex rc Type i No l Serial Number Index 0 2 01 01 00 3 2 47 04 99 0 3 01 01 00 3 2 33 04 99 0 4 03 01 00 3 2 80 99 99 0 5 10 01 00 3 1 56 99 99 0 6 0 7 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 Duress 9 2 00 00 I I Keypad Panic 1 9 5 00 00 00 I I Keypad ...

Страница 19: ...lay 14 Carbon Monoxide 20 Arm Stay 21 Arm Away 22 Disarm 23 No Alarm Response 24 Silent Burglary rc ALARM REPORT CODE Two Hex Digits For each Hex Digit enter 00 09 for 0 9 10 for A 11 for B 12 for C 13 for D 14 for E 15 for F If 00 is entered as the first digit there will be no report for that zone For Contact ID reporting this is enabling code only Enter any hex digit other than 00 in the first p...

Страница 20: ...2 or 3 from Field 81 or 0 Not Used START ZONE LIST Upon alarm fault or trouble of ANY zone on this list device action will START STOP RESTORE of ZONE LIST Upon restore of ALL zones on this list device action will STOP It need not be same list as used for START Note Do not assign zones with types 20 21 or 22 to a zone list 3 ZT ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 07 24...

Страница 21: ...e Record desired zone numbers below More or fewer boxes than shown may be needed since any list may include any or all of a system s zone numbers Zone List 1 Started or stopped by zone numbers enter 00 to end entries etc 28 32 Zone List 2 Started or stopped by zone numbers enter 00 to end entries etc 29 33 Zone List 3 Started or stopped by zone numbers AND OR assignment of Chime zones enter 00 to ...

Страница 22: ...ree n R ed Yellow AR ME D RE AD Y MESSAGE MIC Notes 1 You must enroll loop 4 on the 5801 5804 5804E and 5804BD 5804BDV transmitters regardless of whether it is used or not 2 5804E encrypted High Security devices must be activated while the system is in Go No Go Test Mode Refer to the transmitter s installation instructions for complete details The system will confirm enrollment of the encrypted de...

Страница 23: ...LYNXR I COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION No 5GBUSA 25623 AL E RINGER EQUIVALENCE 0 6B NOTE USE ONLY THE K10145X10 CLASS 2 TRANSFORMERS PROVIDED APX32ENSIA SUMMARY OF CONNECTIONS THE APX32ENSIA CONTROL IS COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL FUTURE USE REPLACE EVERY FOUR YEARS ...

Страница 24: ...5132 North 300 West Provo Utah 84604 800 216 5232 www apxalarm com ÊK14116 8xŠ K14116 8 11 07 Rev A ...

Отзывы: