Problem
Cause
Solutions
The seeding shaft does not
rotate when the implement is in
working position!
Seeding shaft is not
switched on.
Forward speed is 0.
No linkage signal.
Switch on the seeding shaft,
the seeding shaft must be
switched on manually one
time at the beginning.
Check the settings for the
speed sensor
– see Point
Check the speed sensor.
Check the linkage sensor.
A fill level sensor is installed,
but does not transmit!
No signal from the fill level
sensor.
The fill level sensor is
deactivated, see Point
6.3.2.
Adjust the sensitivity of the fill
level sensor (screw on the
rear side).
Reposition the fill level sensor.
Check the plug and cable.
Fill level sensor is constantly
transmitting!
Poor sensor setting.
Poor sensor position. .
Adjust the sensitivity of the fill
level sensor (screw on the
rear side).
Reposition the fill level sensor.
Deactivate the fill level sensor,
see Point 6.3.2.
No speed signal!
Speed signal is not
available on the ISOBUS.
Wrong speed signal was
selected.
Check the settings for the
speed sensor
– see Point
No linkage signal!
Linkage sensor was not
detected.
There is no linkage signal
issued on the ISOBUS.
Check the signal source.
If external linkage sensors are
equipped, check them.
Magnet sensor: the sensor
and magnet must be precisely
opposite to each other when
in working position or in lifted
position.
A forward speed of 0.0 km/h is
displayed or it keeps jumping
back to 0.0 km/h!
Wrong speed signal
detected or selected.
Check the speed sensor
settings (Point 6.3.4).
Spread rate in kg/ha or
seeds/m² is not being
displayed!
A valid calibration test
was not performed.
Values were retroactively
changed in the Calibration
test menu.
Perform a calibration test.
Load the seed type again from
the library.