44
Display
Cause
Solutions
Fan speed too low!
Only with hydraulic/external fan:
Seeding shaft I AND/OR II
active.
The fan speed is below the
minimum speed.
Switch on the hydraulic fan.
Increase the fan speed.
The pulses per revolution
parameter is set incorrectly,
see Point 6.3.8.2.
The fan speed limit was
incorrectly set, see Point
6.3.8.2.
Motor not connected (seeding
shaft I)!
Motor not connected (seeding
shaft II)!
Is displayed when the
implement cable is not
connected or the cabling is
faulty.
Check if the implement
cable is connected.
Check the cabling.
Check the plugs.
No motor speed (seeding shaft)! Power consumption at the
motor, but no feedback that it is
rotating.
Check the terminal
connections on the seeder
(especially the ENC
encoder).
Contact Customer Service.
9.5
ERROR - TC "ON" MODE
If the TC mode is switched on, the following messages are issued as errors. As a result, all actuators will
be switched off for these warnings.
Display
Cause
Solutions
TC units inconsistent! Boom I
TC units inconsistent! Boom II
The units for the specified
values from the Task Controller
do not match the expected
units.
TC units must be verified.
TC specification no longer
available I
TC specification no longer
available II
The Task Controller must be
used (TC mode: ON), but it is no
longer available on the tractor
side.
Check the Task Controller.
10
PROBLEM SOLVING
Problem
Cause
Solutions
The seeding shaft rotates when
the implement is lifted!
Wrong linkage signal.
Linkage signal is not
available on the ISOBUS.
Invert the linkage signal on
the controller, see Point 6.3.4.
Reposition the linkage sensor.
Содержание ISOBUS M2