SECTION 7: CONNECTORS, APPLICATIONS & PROTECTION FEATURES
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
42L Series Modular DC Load Operation Manual
Page 45 of 88
KEY# Description
Setting lower limit power W_Lo:
Middle 5 digit LCD displays
[
W_Lo
]
, lower 5 digit LCD displays the
unit in "W". The W_Lo set range is from 0.00W to 250.00W. Adjust in 0.01W steps by rotating the
dial.
Setting NG ON/OFF:
When NG is turned on (turn dial for
On
or
OFF
), a
NG
indication will be displayed
when any of the set measurement limits is exceeded.
16
DYN setting key and LED
DYN setting key is to set the Dynamic Mode parameters. They are rise, fall, Thigh and Tlow.
Parameters can be changed using the rotary knob. Press any key to escape the DYN parameter
setting mode.
1.
Press DYN setting key, LED will turn ON
2.
Setting level High Period: Middle 5 digit LCD display will show “T-Hi”, left 5 digit LCD display
will show setting value. The unit is “ms”
3.
Setting level Low period: Middle 5 digit LCD display will show “T-Lo”, left 5 digit LCD display
will show setting value. The unit is “ms”
4.
Setting rise time: Middle 5 digit LCD display will show ”RISE”, left 5 digit LCD display will
show setting value. The unit is “(m)A/us”
5.
Setting fall time: Middle 5 digit LCD display will show ”FALL”, left 5 digit LCD display will
show setting value. The unit is “(m)A/us”
The screen images below show the sequence of screens and parameters available to set on each
screen. For additional information on using the DYNAMIC mode, refer to section 3.3, ”Static versus