User's Manual
Index
Purpose
Values (bold: default setting)
Studer
13 ‡
96k
14 ‡
64
48k
15 ‡
96k
24 ‡
DiGiCo
56
48k
MDIX
(Crossover)
25 ‡
96k
26 ‡
64
48k
27 ‡
96k
28 ‡
Soundcraft/
Studer
56
48k
29 ‡
96k
30 ‡
64
48k
31 ‡
96k
32
AES-X213
57
48k
Auto
33
96k
40 ‡
DiGiCo
57
48k
Straight
required
41 ‡
96k
44 ‡
Soundcraft/
Studer
57
48k
45 ‡
96k
56 ‡
DiGiCo
57
48k
MDIX
(Crossover)
57 ‡
96k
60 ‡
Soundcraft/
Studer
57
48k
61 ‡
96k
General: Using the MADI-TP port as AES50 or vice versa is possible, but
requires a pinswap cable (see chapter 13.1) due to the different pinout.
[06]
Wordclock output
mode
*00 = Wordclock output frequency identical to sample rate
01 = Wordclock output frequency is always single speed (base sample rate)
[07]
MIDI channel
01...16.
Default: 01.
NOTE: This is a per-preset setting: remember to change on all presets!
[08]
MIDI forwarding
Configures from/to which MADI interface the data on the MIDI jacks is
routed.
*00 = Disabled
01 = MADI optical
02 = MADI coaxial
03 = MADI-TP
04 = AES50 (in MADI-TP mode only)
[09]
Reserved
[10]
Display brightness
01...05.
Default: 05
[11]
Service menu
01 = Self-test (external cabling required, see
9.5. Audio Interface self-test
self-test
99 = Reset to Factory Defaults
36