MVR-64
4. PRESETS
All settings (excluding headphones level) can be individually stored in one of the
12 preset locations, and may be recalled at any time later. The settings are stored
in non-volatile memory and are retained for years even if the device is switched off
or the power cable is unplugged. Additionally, the settings can be downloaded via
the Web UI, and restored on the same or a different device.
4.1.
Preset Recall
▶ Front panel,
Front panel
To recall a preset:
Push the
Recall
button from the “Preset” menu.
Select the desired storage location
☼
1
to
☼
12
by turning the encoder left or
right.
Note: The presets “Test tone” and “Function” have special purposes.
See 9. Advanced Topics.
Confirm the selected location by pushing the encoder, or push the
⮌
Back
button to cancel the operation.
▶ Front panel,
Web
From the "PRESET " menu, choose the desired preset number. An asterisk next
▼" menu, choose the desired preset number. An asterisk next
to the number indicates that modifications to the recalled preset have been done.
To save the modifications, choose "PRESET / Store".
Note: You can also upload presets from a file to the MVR. This is useful when
transferring setups between different multiverters.
▶ Front panel,
Command line
preset recall <num>
▶ Front panel,
MIDI
Preset recall is done via "Program Change" messages
(program 00 = Preset 1 ... program 11 = Preset 12).
The MIDI channel is set to 1 by default but can be altered using function "07".
(Note: The channel is a per-preset setting, if you need to change it you will need to
do so in all 12 presets).
19