11
code HC0100.00GB ed.A-1509
HY
AQUAPUMP HYBRID
HYBRID HEATER
2.1.
Safety and health of workers
With reference to safety and health of workers, the European
Community issued Directives that the employer has the obligation
to comply with and enforce: 89/391/EEC, 89/686/EEC, 89/655/
EEC, 86/188/EEC and 77/576/EEC.
Therefore:
It is forbidden to tamper with or replace
any machine parts without express
authorisation of the manufacturer. Such
operations relieve the manufacturer from
any civil and criminal liability.
The use of components, consumables
or spare parts different from those
recommended by the manufacturer and/
or indicated in this manual may constitute
a danger for the operators and/or damage
the machine.
The operator workstation must be kept
clean, ordered and free from objects
that can limit his/her free movement.
The workstation must be adequately
illuminated for the operations provided.
Poor or excessive lighting may pose risks.
Make sure that a suitable workspace
ventilation is always ensured and that
suction systems are always operational,
in excellent conditions and in compliance
with legal requirements.
2.2. Personal protective equipment
While using and maintaining the units, personal protective
equipment must be used, i.e.:
Clothing: The operator that carries out
maintenance or uses the system must
compulsorily wear clothing compliant
with the essential safety requirements in
force. Moreover, he/she must wear safety
shoes with non-slip sole, in particular in
environments with slippery floor.
Gloves: Suitable protective gloves must
be used during cleaning and maintenance
operations.
Mask and goggles: A respiration
protection mask and goggles
must be used during cleaning
operations.
2.3.
Safety signals
The unit is provided with the following safety signals, that the
staff must necessarily respect:
General danger
Dangerous electrical voltage
Presence of moving parts
Presence of surfaces that may cause injury
Please find below the safety regulations for the installation room
and the air vents.
2.4. Fuel
Before starting up the heater, make sure that:
• the gas mains supply data are compatible with the data
stated on the nameplate;
• the combustion air intake ducts and the fume exhaust pipes
are only those specified by Apen Group;
• the fuel intake internal and external seal is checked during
the testing stage, as required by applicable standards;
• the boiler is supplied with the same type of fuel it has been
designed for;
•
the system is correctly sized for such flow rate and is fitted
with all safety and monitoring devices required by applicable
standards;
• the internal cleaning of gas pipes has been correctly car-
ried out;
•
the fuel flow rate is suitable for the power required by the boiler;
•
the fuel supply pressure is between the range specified on
the nameplate.
2.5.
Gas Leaks
If you smell gas:
•
do not operate electrical switches, telephones or any other
object/device that could produce sparks;
•
immediately open doors and windows to create an air flow
to vent the gas out of the room;
•
close the gas valves;
•
call for
qualified staff.
Содержание Aermax Series
Страница 2: ...2 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 4: ...4 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 5: ...5 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 6: ...6 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 60: ...60 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...