3.1. Technical Data
GENERAL TECHNICAL DATA OF AQUAPUMP HYBRID
HY434
HY534
Seasonal space heating energy efficiency [Reg.813/2013/EC]*
133%
134%
Energy efficiency class [Reg.811/2013/EC]*
A++
A++
Rated Performance
Boiler
Burner heat output [min-max]
kW
8.0 - 34.8
8.0 - 34.8
Useful output [min-max] (1)
kW
8.5 - 36.2
8.5 - 36.2
Efficiency (1)
%
106.3 - 103.9
106.3 - 103.9
Heat pump
Power during heating [min-max] (2)
kW
4.7 - 12.28
6.3 - 13.88
C.O.P. (2)
W/W
4.10
4.10
Power during cooling [min-max] (3)
kW
3.7 - 7.71
4.8 - 9.88
E.E.R. (3)
W/W
2.91
2.90
Absorbed power (4)
kW
3.16
3.56
Electrical Characteristics
Power supply
230V/1/50Hz
400V/3P+N+T/50Hz
Maximum power consumption
kW
5.81
7.95
Maximum inrush current
A
16.4
7.5
Maximum absorbed current
A
25.4
11.5
Operating Temperatures
°C
-12°C to +45°C
-12°C to +45°C
Protection Rating
IPX5D
IPX5D
Hydraulic circuit
Maximum circulator power
kW
0.076
0.076
Expansion reservoir
l
8.0
8.0
Maximum working pressure
bar
3.0
3.0
Water content
l
5.0
5.3
Minimum system water content
l
35
45
Size and weight
Delivery/return connections - UNI ISO 7/1 -
Ø
G 1" M
G 1" M
Gas connection
Ø
G 3/4" M
G 3/4" M
Dimensions (WxHxD)
mm
1258x1402x448
1258x1402x448
Max package dimensions (WxHxD)
mm
1430x1546x690
1430x1546x690
Weight with packaging
Kg
165
170
Noise
Sound pressure (5)
dB(A)
46÷-54
46÷-54
(*) Package Efficiency: HP + temperature control (calculated with class I control and HP performance at 35°C), for further details
see par. 8
1.
Calculated on L.C.V., with water 60/35°C
2.
external air temp. 7°C dry bulb /6°C wet bulb; in/out water temp. 30/35°C
3.
external air temp. 35°C; in/out water temp. 12/7°C
4.
external air temp. 7°C dry bulb /6°C wet bulb; in/out heat pump water temp. 30/35°C
5.
Sound pressure level on a free field (1 m), according to ISO 3744
WARNING: the minimum permitted temperature for unit storage is 5°C
Содержание Aermax Series
Страница 2: ...2 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 4: ...4 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 5: ...5 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 6: ...6 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...
Страница 60: ...60 code HC0100 00GB ed A 1509 HY AQUAPUMP HYBRID HYBRID HEATER...