GLT-261-7-3  

Doc:   GLT-261-7-1                                     Issue:     W.I.P                          Date: 25/08/2018 

Doc: GLT-261-7-12                                                Issue: 001                                                         Date: 08.02.2021 

 
 
 
 
 

 

MULTI-LOOP REPEATER

 

 
 
 
 
 
 

 

 

 

Installation Manual 

Содержание Smart Connect Multi-loop

Страница 1: ...GLT 261 7 3 Doc GLT 261 7 1 Issue W I P Date 25 08 2018 Doc GLT 261 7 12 Issue 001 Date 08 02 2021 MULTI LOOP REPEATER Installation Manual...

Страница 2: ...Panel Installation and Dimensions 5 Enclosure Dimensions 5 Panel Construction Details 5 Locating the Fire Alarm Control Panel 5 Mounting the Enclosure 6 Mounting Hole Dimensions 6 Planning Cable Entry...

Страница 3: ...all control panel electronic hardware system memory components and the system program A hardware watchdog circuit is provided to ensure that System programs are functioning properly If a problem devel...

Страница 4: ...4 Typical Smart Network Fire Alarm Wiring System Components Display PCB MMP DSP 4 3 colour touch screen display 32 bit microcontroller MCU USB connection to PC software 2 key switch inputs Termination...

Страница 5: ...9005 Black Leatherette The repeater enclosure can be semi flushed into a wall or surface mounted Locating the Fire Alarm Control Panel The control panel should be installed per BS5839 1 2017 recommend...

Страница 6: ...8 roundhead or countersunk woodscrews or similar Remove any debris from the enclosure Take care not to damage the panel during installation Mounting Hole Dimensions Fig 1 Planning Cable Entry The Knoc...

Страница 7: ...r and fused at 5A This should be secure from unauthorized operation and be marked FIRE ALARM DO NOT SWITCH OFF The supply must be exclusive to the repeater Connecting the DC Power The incoming DC powe...

Страница 8: ...Smart Connect Multi loop Repeater Installation Manual www zetaalarmsystems com 8 Figure 3 28V DC wiring Figure 4 28V DC terminal wiring ATTENTION CHECK POLARITY IS CORRECT BEFORE TURNING THE POWER ON...

Страница 9: ...turn off Power LED will blink a few times c LCD will show touch for calibration Press the screen within 3 seconds to perform a screen calibration The screen is calibrated at the factory so this step...

Страница 10: ...stance Between Nodes 1KM with screened data cable 100M using a standard fireproof cable Communication Protocol RS485 Network Wiring Typologies Bus or Ring BS 5839 1 2017 requires that network cable be...

Страница 11: ...using a standard fireproof cable Network Wiring Typologies Bus Ring recommended Software Maximum Event Log 8032 Events Software Programming Touchscreen LCD Display LCD 4 3 Resistive touch screen 480 x...