4. Load Cell Installation
PNEG-2340
Feed-Link 2
15
Installing the Load Cell Base
1. Shortening the anchor bolt may be required.
It can protrude no more than 1-1/4" above the
foundation.
NOTE: You may
find it easier to put the nut on the bolt and cut
the bolt flush with the nut. This way the
threads are not stripped on the bolt and there
is not a problem getting the nut on.
2. Position the load cell base under the bin leg
and around the anchor bolt as shown.
3. Replace washer and nut onto the anchor bolt.
DO NOT tighten fully until assembly is
complete.
Figure 4F Cut anchor bolt so it sticks up less than
1-1/4" from foundation.
Figure 4G Slide Cell Base Under Leg
Figure 4H Leave anchor bolt loose until
assembly is complete.