CHEESE MELTER
P/N 1010983 Rev. F 05/19
®
TROUBLESHOOTING (continued)
Problem
Possible Cause
Corrective Action
Insufficient water entering
Generator casting.
If Ready light does not light but the unit
steams regularly, the Ready light is
inoperable.
Contact your maintenance person or
Authorized Service Agency.
If the Ready light does light and the
unit does not steam, the control board
is inoperable.
Contact your maintenance person or
Authorized Service Agency.
*(Direct Feed Units) Quick-disconnect
not connected properly or inoperable.
Make sure the quick-disconnect and
O-ring are properly positioned and
are not damaged. Replace damaged
parts.
Water volume adjustment is too low.
Adjust the water volume control. See
Calibration section of the manual.
Water Filter clogged.
Remove and clean Water Filter.
Inoperable solenoid or solenoid dam-
age caused by connecting a hot water
supply line.
Make sure unit is connected to a cold
water supply. Contact your mainte-
nance person or Authorized Service
Agency.
Inoperable Control Board.
Contact your maintenance person or
Authorized Service Agency.
Steam coming out around
top cover or sides.
Wing Nut is loose.
Tighten Wing Nut.