EVDO Demodulator
To demodulate CDMA2000 EVDO signals, connect the Cell Master to the base station.
Step 1.
On the Cell Master, press the
MODE
key, use the Up/Down arrow key to select
the
EVDO
mode and press
ENTER
.
Step 2.
Select the
Signal Standard
soft key and press the
Select Standard
soft key. Use
the soft keys or the Up/Down arrow key to highlight the appropriate standard,
such as CDMA US PCS, and press
ENTER
.
Step 3.
Press the
Select Channel
soft key and use the Up/Down arrow key or the nu-
meric keypad to enter the appropriate channel, such as 50, and press
ENTER
.
Step 4.
Press the
MEAS/DISP
key and select the
Setup
soft key.
Step 5.
Press the
PN Search
soft key and choose
External Auto
when the Cell Master is
connected to the base station.
NOTE: With GPS OTA measurements, select the GPS Auto soft key after the
GPS is synchronized.
Step 6.
Press
Back
to return to the previous menu.
Step 7.
Press the
Data Modulation Type
soft key and select
Auto
or, to select a particular
modulation type, select the appropriate soft key.
Step 8.
Press
Back
twice to return to the measurements menu.
Step 9.
Press the
CDP
soft key and select the
MAC Code Power
or
Data Code Power
soft key to display the MAC Code Power or Data Code Power screens.
Chapter 18 EVDO Mode
18-9
Figure 18-3.
MAC Code Power Screen
Содержание Cell Master MT8212B