
Step 3.
To display the measurement data in a histogram format, press the
Display Raw
Data/Histogram
soft key.
Step 4.
Press the
Measure Duration
soft key to set the duration of the measurement, and
press
ENTER
. The maximum measurement duration is two days.
Step 5.
Press the
Time Scale
soft key and use the
Up/Down
arrow key to select the histo-
gram resolution, and press
ENTER
. The maximum time scale is 60 minutes.
NOTE
: The unit sets the histogram display and collects and displays the data
based on the selected time scale. For example, if the time scale is set to 30
minutes, the unit collects and updates the histogram display data every 30 min-
utes. When the time scale is set to Auto, the unit automatically sets the histo-
gram display to collect the data based on the selected measurement duration.
Step 6.
Press the
Start/Stop Measure
soft key to begin the measurement.
Step 7.
Press the
SYS
key, then the
Application Options
and
Log Data
soft keys to save
the data. A message window will display if there is insufficient memory to log
the complete duration. Adjust the Measurement Duration and Time Scale as nec-
essary to log the data.
Step 8.
Press the
Start/Stop Measure
soft key to begin the measurement.
NOTE: The
RUN/HOLD
key can also be used to start or stop the measurement.
To Insert Setup Errors
Press the
Insert Errors
soft key to inject errors in the transmit signal while performing the is
E1 measurements. Figure 10-8 illustrates the E1 measurement when the errors are inserted
and it is displayed on the right side at the bottom of the display.
10-10
Chapter 10 E1 Measurements
Figure 10-8.
E1 Measurement Display with Errors Inserted
Содержание Cell Master MT8212B
Страница 3: ......
Страница 5: ......
Страница 222: ...12 4 Chapter 12 GPS Feature Figure 12 3 Saved GPS Location Information...
Страница 231: ...Chapter 13 CDMA Measurement 13 9 Figure 13 5 CDMA Display with Markers...
Страница 255: ...Chapter 18 EVDO Mode 18 5...