3-4 ME7838A/E System Verification Procedure—Broadband System Configuration Performance Verification
3-4
PN: 10410-00306 Rev. F
VectorStar ME7838 Series MM
9.
If the verification fails, check the connectors of the test ports on the 3743A/E Millimeter-Wave modules,
calibration components, and the verification standards for damage, cleanliness, and proper connection
and torquing. Also check connections of the interconnect RF/IF coaxial cables and their phase stability.
These are the most common causes for verification failures.
Note
Due to different calibration methods are required to cover the 110 GHz range (SOLT for low band
and SSST for high band), the verification is done in two steps
Low band and High band with the
break point set to 65 GHz.