99
feeding-motor
adjustment
feeding-motor
adjustment
*The parameters with mark “*” should be changed under the guide of the professional
technicians.
【
Note1
】:
The range of parameter P11-12 and P11-13 could be different for different
manufactory.
(
Parameter List for Single Stepping Model
)
Code
Name
Description
Unit
Step
Range
Default
Type
P11-0*
Max Speed
Set Max speed for
each head
rpm
50
50~5000
3000
Input
P11-1*
Frame-moving
Method
Set frame-moving
method
1
0~5
1
Input
P11-2*
Swing Motor
Current
Set swing motor
current
1
0~15
5
Input
P11-3*
Swing Motor
Semi-current Value
Set swing motor
semi-current
1
0~15
4
Input
P11-4
Display of Pause
Button
Display the pause
button or not
NO
:
Not display
YES
:
Display
YES
Selection
P11-5*
Pick-up Delay Time
Delay time at
picking up thread
ms
1
0~250
170
Input
P11-6*
Feeding Action
Angle Adjustment
Adjustment of
frame-moving angle
at feeding
1
-50~50
0
Input
P11-7*
Thread-trimming
Angle Adjustment
Adjustment of
thread-trimming
angle
1
-30~30
0
P11-8
Main Controller
Burning Address
0xA0000
0xB0000
0xC0000
0xD0000
0xA0000
*The parameters with “*” shall be modified under the guide of the professional technician
3.13.3 Parameter Recovery and Back-up
User can save the changed parameter into U disk for the recovery operation in future
www.garudan.cz