91
description on that parameter.
3.13.2Parameter List
1
、
General Parameters
:
Code
Brief
Description
Unit
Step
Length
Range
Default
Val ue
Type
P1-0
Swing Type
Set the swing method in
system
0:CEN:Center
Symmetry
1:LR:LR
Symmetry
0
Selection
P1-1
Center
Symmetry
Swing
Limits
The swing range at
center symmetry
mm
0.1
0~10.0
10.0
Input
P1-2
Swing Left
Limits (LR
Swing)
Set down left limits in
LR Swing method
mm
0.1
-5.0~0
-4.0
Input
P1-3
Swing
Right
Limits (LR
Swing)
Set down right limits in
LR Swing method
mm
0.1
0~5.0
4.0
Input
P1-4
Base Line
Position
Base line position
setting
0:CEN:Center
1:L:Left
2:R:Right
0
Selection
P1-5
Contrary
Feeding
Limits
Set the contrary feeding
limits
mm
0.1
-5.0~5.0
-5.0
Input
P1-6
Normal
Feeding
Limits
Set the normal feeding
limits
mm
0.1
-5.0~5.0
5.0
Input
www.garudan.cz