93
P2-6* Reverse Sewing
Total Pressure
Output Time
Set the total pressure
control time of the
reverse solenoid
ms
1
50~250
100
Input
P2-7* Reverse Sewing
Output Duty
Cycle
Set the current when the
reverse solenoid is
holding
1
0~100
40
Input
*The parameters with mark “*” should be changed under the guide of the professional
technicians.
3
、
Main-shaft and Speed:
Code
Brief
Description
Unit
Step
Length
Range
Default
Val ue
Type
P3-0
Soft Start Stitch
Number
Set the stitch number of soft
start at sewing
Stitch
1
0~9
3
Input
P3-1* Soft Start Speed
Set the speed at soft start
rpm
50
150~5000
1200
Input
P3-2* Reverse Sewing
Speed
Set the Max speed at reverse
sewing
rpm
50
150~3000
1500
Input
P3-3
Min Speed
The Min Speed
rpm
10
20~400
200
Input
P3-4
Sewing Speed at
One Time
Set the speed at an automatic
sewing
rpm
50
200~5000
3000
Input
P3-5* Down Needle
Stop Angle
Down Needle Stop Angle
Degree 10
120~200
160
Input
P3-6
Needle
Conversion at
Trimming
Set the function for converting
the needle after trimming
0:OFF: No
1:ON:Yes
0
Selecti
on
P3-7
Conversion
Needle Angle
Set the angle for converting the
needle
Degree 1
0~45
20
Input
P3-8* Main shaft angle
adjustment
Adjust the main shaft angle. It
is only effective for the
integrated motor.
Degree
1
-30~6
0
Input
P3-9* Main motor
Selection
Select the type of main shaft
motor
0
:
Normal
Motor
1
:
Integrated
motor
1
Selecti
on
*The parameters with mark “*” should be changed under the guide of the professional
technicians.
4
、
Thread-trimming
:
Code
Brief
Description
Unit
Step
Range
Default
Type
www.garudan.cz