400V three phase TV/SG1F Board electrical connection
The customer is responsible for the machine's electrical connection,
to be carried out by qualified technical personnel.
Connect the machine following the wiring diagram and components' features
given below.
Ensure the electrical power supply has the same features as those on the
technical data plate.
Respect the technical standards and laws in the place and at time of installation.
(install the following devices or others with equal features)
Electric energy must have the following requirements according to machine model:
DESCRIPTION
DATA
IDM
Circuit breaker differential switch
4P
Brand
ABB
For 3.5 kw boiler heating element Model
DS 674 C20
For 5 or 7 kw boiler heating element Model
DS 674 C25
Series
DS 670
Nominal voltage
V 400
Tripping curve
C type
Nominal current
In 20A for DS 674 C20
Nominal current
In 25 A for DS 674 C25
Nominal short-circuit current
Icn 10 KA
Residual breaking capacity
I
∆
m 0.03 A
S2
2P Selector
400 V~
For 3.5 kw Nominal current boiler heating element
20 A
For 5 or 7 kw Nominal current boiler heating element
25 A
Technical data
V
400-3
Hz
50-60
Total watts
6100
Total amp.
17
ICC
10 KA
Technical data
V
400-3
Hz
50-60
Total watts
7600
Total amp.
20
ICC
10 KA
Technical data
V
400-3
Hz
50-60
Total watts
9600
Total amp.
23
ICC
10 KA