The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the da-
taplate); conversion to 230V/3 can be carried out as
described below.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Open the hatch
(B)
.
2 - Undo the screws
(C)
and remove the lid
(D)
.
3 - Fit the jumper
(E)
to make the electrical con-
nection of the terminals
(F)
.
4 - Change the connections of the terminal board
(G)
as shown in the diagram.
5 - Replace the lid
(D)
and fix it with the screws
(C)
on completion of the operation.
(B)
7 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used
Important
On completion of the operation make sure
that there are no malfunctions.
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions.
In this stage, it is important to check that all
health and safety requirements have been
complied with in full.
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
that of the appliance.
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Check that the safety device is operating cor-
rectly.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
CONVERSION OF ELECTRICITY SUPPLY
TESTING OF THE APPLIANCE