Maintenance
68
MAXXflo EVO
6.2.15 wATER PRESSuRE SENSOR
• Close both water shut off valves and use one of the drain points to drain down water until no further
release of water occurs
• Carefully remove wiring connector from the sensor - using a small screwdriver to gently lift the tabs on
each side in turn whilst at the same time gently pulling on the connector
• Pull out the metal locking clip, and keep to one side
• Turn and pull out sensor
• Replacement is the reverse
Connector locking
tabs
Pull connector
away from sensor
body
Metal locking clip