Technical Data
16
MAXXflo EVO
EXAMPLE 3: MAXXFLO EVO & STORAGE TANK (SCHEMATIC)
Menu
Parameter
Settings
Configuration
6020
Set function of extension module 1 to “Multifunctional”
6030
Set Relay Output QX21 module 1 to “dT controller 1 K21”
6041
Set sensor input BX22, module 1 to “Special temperature sensor 1”
General func
-
tions
5570
Factory setting : Not used
5571
Factory setting: “- 1.5
O
C” - When BUFFER SS300-10 tank temperature is 0.5
O
C below
MAXXflo EVO tank temperature K21 pump will be turned off.
5572
Factory setting: “3.0
O
C” - When BUFFER SS300-10 tank temperature is less than 2.0
O
C
below MAXXflo EVO tank temperature K21 pump will be turned on.
5573
Factory setting : “DHW sensor B3”
5574
Factory setting : “Special temperature sensor 1”
5575
Factory setting : 30 seconds - Represents the minimum time that K21 pump will be activated
even if parameter 5571 conditions are met.
Related settings table (in addition to example 1 table)