Installation
34
MAXXflo EVO
4.7.13
FLuE TERMINAL POSITIONS - C
13
C
33
C
53
C
63
TyPE (CONCENTRIC / TwIN)
Code Minimum distance (mm)
Model
CwH90 CwH120
A
Directly below an opening, air brick, opening window etc
2500
B
Above an opening, air brick, opening window etc
700
900
C
Horizontally to an opening, air brick, opening window etc
700
900
D
Below gutters, soil pipes or drainpipes
200
E
Below eaves
200
F
Below a balcony or car port roof
*not recommended
G
Above ground, roof or balcony level
300
H
From vertical drain or soil pipe
150
J
From an internal or external corner to an alongside boundary
300
K
From a terminal facing a terminal
2,270
2,810
L
Vertically from a terminal on the same wall
2,500
M
Horizontally from a terminal on the same wall
700
900
N
From a surface or a boundary line facing a terminal
2,600
3,200
P
From a opening in a carport (e.g. door, windows) into the building
*not recommended
Q
Above a pitched roof
370
490
R
From a roof structure
2500
S
Above a flat roof
370
490
From any other roof flue terminal
770
900
* - Risk assessment required
Terminals should be so
positioned as to avoid
products of combustion
entering openings into
buildings or other flues or
vents