![AND AD-4430B Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/and/ad-4430b/ad-4430b_instruction-manual_2941312035.webp)
AD-4430B
- 33 -
5.4.3.
The Basics Function
(
)
Function No.
Parameter
and range
Item name
Description
Default
value
0000 to 1111
Key switch
disable
Each digit of the setting corresponds to a key switch.
Only available in the weighing mode.
0
:
Enables
Key assignment to each binary digit.
1
:
Disables
4th
3rd
2nd
1st
0000
(2binary)
0 to 7
key function
0
:
None
1
:
Manual print command
2
:
Hold
3
:
Alternate switch
4
:
Momentary switch
5
:
Changing between gross weight and net weight
6
:
Clear the tare weight
7
:
Clear the zero value
NOTE: Clearing the zero value can be enabled or
disabled by
.
5
5 to 20
Display update
rate
20 times/second
10 times/second
5 times/second
20
0 to 9
x display
0
:
None
1
:
Zero tracking in progress
2
:
Alarm (Zero range setting error, over)
3
:
key status
4:
:
Near-zero
5
:
HI output (Over the upper limit value)
6
:
OK output (Between upper and lower limit values)
7
:
LO output (Below the lower limit value)
8
:
User input 1
9
:
User output 1
0
0 to 16
Digital filter
Selects a cutoff frequency.
0
:
None
1
:
100.0 Hz
9
:
7.0 Hz
2
:
70.0 Hz
10
:
5.6 Hz
3
:
56.0 Hz
11
:
4.0 Hz
4
:
40.0 Hz
12
:
2.8 Hz
5
:
28.0 Hz
13
:
2.0 Hz
6
:
20.0 Hz
14
:
1.4 Hz
7
:
14.0 Hz
15
:
1.0 Hz
8
:
10.0 Hz
16
:
0.7 Hz
15
1 to 3
Hold function
1
:
Normal hold
2
:
Peak hold
3
:
Averaging hold
1
-99999 to
99999
Near-zero
The reference value for near-zero.
Decimal point position is linked to
.
10