SMART CUT 2™ Chapter 10 : RS-232 PROGRAMMER'S GUIDE
PAGE 35
10-5. COMMANDS DESCRIPTION (continued)
- SMART CUT 2
™
+ SMART SWITCH AUDIO
™
APPLICATION.
DECIMAL
VALUE
INPUT # SELECTION
RESPONSE
APPLICATION
0
AUTOMATIC
ACHAN0
2
EXTEND PC 2
ACHAN2
4
EXTEND C.VIDEO 2
ACHAN4
6
EXTEND S.VIDEO 2
ACHAN6
8
C.VIDEO 1
ACHAN8
9
C.VIDEO 2
ACHAN9
10
C.VIDEO 3
ACHAN10
11
C.VIDEO 4
ACHAN11
12
C.VIDEO 5
ACHAN12
13
C.VIDEO 6
ACHAN13
S-CUT 2
14
S.VIDEO 1
ACHAN14
+
15
S.VIDEO 2
ACHAN15
SMA415
16
S.VIDEO 3
ACHAN16
+
17
S.VIDEO 4
ACHAN17
SMV415
18
S.VIDEO 5
ACHAN18
19
S.VIDEO 6
ACHAN19
20
RGB / YUV 1
ACHAN20
21
RGB / YUV 2
ACHAN21
22
RGB / YUV 3
ACHAN22
23
COMPUTER 1
ACHAN23
24
COMPUTER 2
ACHAN24
25
COMPUTER 3
ACHAN25
g
STATUS COMMANDS (READ ONLY).
This control family is read only ; it cannot be preceded by a value.
•
U command
returns the UNIT value, used to calculate the computer line and frame frequency.
•
l command
returns the Computer Line Duration (CLD value).
The following formula allows to calculate the input line frequency in kHz.
UNIT VALUE = Input line frequency in kHz.
CLD VALUE
•
t command
returns the Computer lines per Frame (CFD value).
The following formula allows to calculate the computer input frame frequency in Hz.
INPUT LINE FREQUENCY (Hz) = Input frame frequency in Hz.