SMART CUT 2™ Chapter 10 : RS-232 PROGRAMMER'S GUIDE
PAGE 33
10-5. COMMANDS DESCRIPTION (continued)
d
OUTPUT COMMANDS
•
u command
is used to select the reference sync.
- SMART CUT 2
™
ALONE APPLICATION.
DECIMAL
VALUE
SELECTION
RESPONSE
APPLICATION
0
INTERNAL RATE
SSYNC0
1
COMPUTER 1
SSYNC1
S-CUT 2
2
COMPUTER 2
SSYNC2
ALONE
3
VIDEO IN RATE
SSYNC3
- SMART CUT 2
™
+ SMART SWITCH VIDEO
™
APPLICATION.
DECIMAL
VALUE
SELECTION
RESPONSE
APPLICATION
0
INTERNAL RATE
SSYNC0
2
EXTEND PC 2
SSYNC2
3
VIDEO IN RATE
SSYNC3
S-CUT 2
23
COMPUTER 1
SSYNC23
+
24
COMPUTER 2
SSYNC24
SMV415
25
COMPUTER 3
SSYNC25
•
O command
is used to select the output format.
DECIMAL
VALUE
SELECTION (OUTPUT FORMAT)
RESPONSE
APPLICATION
0
VGA (640 x 480) at 60Hz
OFMT0
1
PLASMA 42” (852 x 480) at 60Hz
OFMT1
2
SVGA (800 x 600) at 60Hz
OFMT2
3
MAC (640 x 480) at 66Hz
OFMT3
4
XGA (1024 x 768) at 60Hz
OFMT4
5
PLASMA 50” (1280 x 768) at 56Hz
OFMT5
6
SXGA (1280 x 1024) at 60Hz
OFMT6
7
VGA (640 x 480) at 75Hz
OFMT7
8
PLASMA 42” (852 x 480) at 72Hz
OFMT8
ALL APPLICATIONS
WITH NO COMPUTER
USED AS REFERENCE
SYNC.
9
SVGA (800 x 600) at 75Hz
OFMT9
10
MAC 16” (832 x 624) at 75Hz
OFMT10
11
XGA (1024 x 768) at 75Hz
OFMT11
12
PLASMA 50” (1280 x 768) at 75Hz
OFMT12
13
SXGA (1280 x 1024) at 75Hz
OFMT13
14
D-ILA (1365 x 1024) at 75Hz
OFMT14
NOTE
: The O command is active only if "no computer" is selected as a reference (the response of the n command
should be 0 or 3).
•
o command
is used to select the output sync type.
DECIMAL
VALUE
SELECTION
(OUTPUT SYNC TYPE)
RESPONSE
APPLICATION
0
H & V SEPARATE SYNC.
OSIG0
ALL
1
COMPOSITE SYNC.
OSIG1