background image

SCAN 1600 / DIGI SCAN 1600 

APPENDIX A / ANNEXE A 

 

 

 

PAGE 25 

A-4: COMMANDS AND RESPONSES TABLE 

A-4: TABLE DES COMMANDES ET RÉPONSES 

  COMMAND  RESPONSE 

COMMAND DESCRIPTION 

VALUE /

VALEUR

 

 

COMMANDE  RÉPONSE 

DESCRIPTION DE LA COMMANDE 

TYPE

MIN MAX

DESCRIPTION 

 

FRONT PANEL COMMANDS / COMMANDES DE LA FACE AVANT 

 

FRZ 

FREEZE. 

Rd/Wr

0 = freeze inactive 

1 = freeze active. 

 

ASP 

Size mode selection. 

Rd/Wr

0 = underscan. 

1 = overscan. 

2 = ZOOM. 

 

HP 

Horizontal position adjustment. 

Rd/Wr

255   

 

v VP 

Vertical 

position 

adjustment. Rd/Wr

255 

 

 

w HW 

Horizontal 

size 

adjustment. Rd/Wr

255 

 

 

VS 

Vertical size adjustment. 

Rd/Wr

255   

 

ZHP 

Zoom horizontal position. 

Rd/Wr

255   

 

ZVP 

Zoom vertical position. 

Rd/Wr

255   

 

ZHW 

Zoom horizontal size. 

Rd/Wr

255  0 = 100% 

255 =500% 

 

ZVS 

Zoom vertical size. 

Rd/Wr

255  0 = 100% 

255 =500% 

 

INPUT COMMANDS / COMMANDES D’ENTREE 

 

RGBI 

Input type 

Rd/Wr

0 = analog 

1 = DVI 

 

GP 

REFH 

Genlock H phase adjustment 

Rd/Wr

127  0 = -1.6 µs 

127 = 1.57 µs 

 

GS 

REFS 

Genlock subcarrier phase adjustment.  Rd/Wr

255  0 = -180° 

255 = 180° 

 

GL 

GLD 

Genlock load. 

Rd/Wr

0 = Hi-Z 

1 = 75 ohms. 

 

SOGI 

SOG input selection. 

Rd/Wr

0 = no 

1 = yes. 

 

LOAD 

H sync load selection. 

Rd/Wr

0 = Hi-Z 

1 = 75 ohms. 

 

OUTPUT COMMANDS / COMMANDES DE SORTIE 

 

OFMT 

Output standard selection 

Rd/Wr

0 = NTSC 
1 = PAL 
2 = NTSCj. 

 

GR REFR 

Synchronization 

mode 

selection. Rd/Wr

internal. 

1 = genlock. 

 

OSIG 

RGB/YUV output selection. 

Rd/Wr

0 = YUV. 
1 = RGBS. 
2 = RGsB. 

 

OPAT 

Test pattern selection. 

Rd/Wr

0 = no test pattern. 
1 = test pattern selected. 

 

IMAGE COMMANDS / COMMANDES DU MENU IMAGE 

 

FLK 

Flicker level selection. 

Rd/Wr

 

 

BLK 

Black level adjustment 

Rd/Wr

127  0 = level -64 

127 = level 63 

 

RLV 

Red level adjustment. 

Rd/Wr

255   

 g 

GLV 

Green 

level 

adjustment. 

Rd/Wr

255 

 

 

BLV 

Bleu level adjustment. 

Rd/Wr

255   

 

HSMT 

Horizontal smooth 

Rd/Wr

0 = OFF  

1 = ON. 

 

yp 

PRES 

PRESET 

Rd/Wr

1 = PRESET (automatic reset). 

 

CONTROLS COMMANDS / COMMANDES DE CONTRÔLE 

 

yl 

LOCK 

Front panel locking selection. 

Rd/Wr

0 = unlocks all buttons. 1 = locks all buttons. 

 

yc 

EPOS 

Erase memory. 

Rd/Wr

1 = erase all memories (automatic reset). 

 

FRES 

Default value. 

Rd/Wr

1 = set all the parameters to the default value 
(automatic reset). 

 xu  VERU 

Device 

version 

Rd 

65535 Example: 104 = Version 1.4 

 xi 

I_ 

Identification 

number. 

Rd 

65535 Value displayed in hexadecimal in the device. 

 

NOTE: Rd

 = Read only command / 

Commande de lecture.

 

Rd/Wr = Read and write command /

 Commande de lecture et d'écriture.

 

Содержание Digi Scan 1600

Страница 1: ...ANALOG WAY SCAN 1600 DIGI SCAN 1600 EDITION 06 07 User s Manual MODEL DSV1600 MODEL SSV1600...

Страница 2: ...nplugged from wall outlet In both cases please follow these instructions The power cord of the device should be unplugged from the outlet when left unused for several days To unplug the device do not...

Страница 3: ...mais obstruer ses ouvertures Si un liquide ou un objet p n tre l int rieur de l appareil d branchez imm diatement l appareil et faites le contr ler par un personnel qualifi avant de le remettre en ser...

Страница 4: ...amos que lea cuidadosamente todas las consignas de seguridad y de funcionamiento del aparato antes de usarlo Conserve las instrucciones de seguridad y de funcionamiento para que pueda consultarlas pos...

Страница 5: ...ANEL DESCRIPTION 11 1 10 SCAN 1600 REAR PANEL DESCRIPTION 11 Chapter 2 STARTING 12 2 1 DIGI SCAN 1600 CONNECTIONS 12 2 2 SCAN 1600 CONNECTIONS 13 2 3 SETTINGS 13 2 4 IMAGE ADJUSTMENTS 13 Chapter 3 FRO...

Страница 6: ...devices DIGI SCAN 1600 connection diagram 2 6 3 4 5 5 RGB COMPONENT output connection SETTINGS c We recommend resetting the DIGI SCAN 1600 to all of its default values with the front panel display men...

Страница 7: ...input sources and then your display devices SCAN 1600 connection diagram 2 3 4 5 RGB COMPONENT output connection SETTINGS c We recommend resetting the SCAN 1600 to all of its default values with the...

Страница 8: ...2 meeting SMPTE 259 timing specifications Digi Scan 1600 comes with High performance Genlock to overlay graphics onto incoming Video with external switcher All of the Line Subcarrier phase parameters...

Страница 9: ...be downloaded from Analog Way website Scan 1600 is very easy to use and provides a high quality Video signal 1 5 DEVICES OPTIONS REFERENCES REFERENCE DESIGNATION DSV1600 DIGI SCAN 1600 SSV1600 SCAN 1...

Страница 10: ...ON ON OFF AC power switch O OFF I ON POWER Standard IEC connector 100 250 VAC 0 5A 50 60Hz automatic RS 232 RS 232 communication port on a DB9 female connector INPUT MONITOR COMPUTER INPUT Analog comp...

Страница 11: ...ng push FREEZE Freezes the displayed output short push 1 10 SCAN 1600 REAR PANEL DESCRIPTION RS 232 RS 232 communication port on a DB9 female connector INPUT MONITOR COMPUTER INPUT Analog computer inp...

Страница 12: ...s required connect a control monitor on the MONITOR OUT HD15 connector NOTE Set the RGB Hi Z 75 button on Hi Z if you connect a monitor on the MONITOR OUT connector If not set it on 75 NOTE The MONITO...

Страница 13: ...turn ON your input source and then your display devices SCAN 1600 connection diagram 2 3 4 5 RGB COMPONENT output connection 2 3 SETTINGS c We recommend resetting the device to all of its default val...

Страница 14: ...tton to enter in the CONTROL MODE From the CONTROL MODE press this button to confirm a selected item EXIT MENU button From the STATUS MODE press this button to enter in the CONTROL MODE From the CONTR...

Страница 15: ...4 5 6 7 1 NTSC 59 94 Hz 2 PAL 50 Hz 3 NTSC J 59 94 Hz 8 Preset 7 Zoom status 3 SOG input 4 H sync load 5 Genlock load 1 6 Genlock H ph 1 7 Genlock Sc ph 1 2 Output 1 Output status 2 Output std 3 Outp...

Страница 16: ...SV1600 only This function allows to adjust the genlock Subcarrier phase Adjust with ENTER 2 OUTPUT ENTER 2 1 Output status ENTER Displays the output status 2 2 Output std ENTER Select one of the follo...

Страница 17: ...ER Displays the image zoom status 3 8 Preset ENTER This function allows to set all the image parameters flicker filter Black level RGB level under overscan position size to the factory settings FUNCTI...

Страница 18: ...exe in Start Program ANALOGWAY SCAN1600 updater f In the Port menu select the Com port connected to the device g Click on START on the software h Press and hold the ENTER front panel button and simult...

Страница 19: ...D ROM into your drive the ANALOG WAY home window will open automatically e Select the language of the CD ROM menus then click on Install a Remote Control Software and select the name of your device IM...

Страница 20: ...OFTWARE continued SCAN 1600 DIGI SCAN 1600 PAGE 20 5 4 USING THE SOFTWARE c Click on the Input tab and select the Computer input type d Click on the Output tab and then select the needed adjustment ou...

Страница 21: ...1600 Chapter 5 REMOTE CONTROL SOFTWARE continued PAGE 21 5 4 USING THE SOFTWARE continued e Click on the Image tab and adjust your input f For the DSV1600 only click on the Genlock tab and make the g...

Страница 22: ...120 Hz 800 x 600 60Hz up to 120 Hz 1024 x 768 60Hz up to 120 Hz 1280 x 1024 60Hz up to 75 Hz 1600 x 1200 60Hz RB Reduced Blanking 6 2 VIDEO OUTPUTS RGB S VIDEO Connectors 4 BNC female Frequency 15 62...

Страница 23: ...NTSC Impedance 75 Ohm or Hi Z Output Passive loop through 6 4 REMOTE PORT Connector DB9 female Level RS 232 Data Rate 9600 bauds 8 bits data 1 bit stop no parity bit no flow control 6 5 ENVIRONMENTAL...

Страница 24: ...ni avant ni apr s Il n est pas n cessaire d appuyer sur ENTER du clavier Une commande peut tre pr c d e d une valeur voir chapitre A 2 STRUCTURE D UNE COMMANDE Lorsque l appareil re oit une commande...

Страница 25: ...no 1 yes l LOAD H sync load selection Rd Wr 0 1 0 Hi Z 1 75 ohms OUTPUT COMMANDS COMMANDES DE SORTIE F OFMT Output standard selection Rd Wr 0 2 0 NTSC 1 PAL 2 NTSCj GR REFR Synchronization mode select...

Страница 26: ...no sync detected 1 sync detected ih IHP Sign of the horizontal input sync Rd 0 1 0 negative 1 positive iv IVP Sign of the vertical input sync Rd 0 1 0 negative 1 positive ii IIN Interlaced signal det...

Страница 27: ...8 104 29 41 I 49 73 i 69 105 2A 42 J 4A 74 j 6A 106 2B 43 K 4B 75 k 6B 107 2C 44 L 4C 76 l 6C 108 2D 45 M 4D 77 m 6D 109 2E 46 N 4E 78 n 6E 110 2 F 47 O 4F 79 o 6F 111 0 30 48 P 50 80 p 70 112 1 31 49...

Страница 28: ...s including free materials and labor This warranty does not apply if the product has been improperly installed or abused handled with improper care used or stocked in abnormal conditions modified open...

Отзывы: