background image

 

SCAN 1600 / DIGI SCAN 1600 

 

 

PAGE 2

 

 

ENGLIS

SAFETY INSTRUCTIONS 

All of the safety and operating instructions should be read before the product is operated and should be retained for further 
reference. Please follow all of the warnings on this product and its operating instructions. 

CAUTION: 

WARNING: 

To prevent the risk of electric shock and fire, do not expose this device to rain, humidity or intense 
heat sources (such as heaters or direct sunlight). Slots and openings in the device are provided for 
ventilation and to avoid overheating. Make sure the device is never placed on or near a textile 
surface that could block the openings. Also keep away from excessive dust, vibrations and shocks. 

POWER: 

Only use the power supply indicated on the device or on the power source. Devices equipped with a 
grounding plug should only be used with a grounding type outlet. In no way should this grounding 
be modified, avoided or suppressed. 

POWER CORD:  Use the On (I) / Off (O) switch to power On or Off devices equipped with that switch. All other 

devices should be plugged and unplugged from wall outlet. In both cases, please follow these 
instructions: 

- The power cord of the device should be unplugged from the outlet when left unused for several 
days. 

- To unplug the device, do not pull on the power cord but always on the plug itself. 

- The outlet should always be near the device and easily accessible. 

- Power supply cords should be routed so that they are not likely to be walked on or pinched by 
items placed upon or against them. 

If the power supply cord is damaged, unplug the device. Using the device with a damaged power 
supply cord may expose you to electric shocks or other hazards. Verify the condition of the power 
supply cords once in a while. Contact your dealer or service center for replacement if damaged. 

CONNECTIONS:  All inputs and outputs (except for the power input) are TBTS defined under EN60950. 

SERVICING: 

Do not attempt to service this product yourself by opening or removing covers and screws since it 
may expose you to electric shocks or other hazards. Refer all problems to qualified service 
personnel. 

OPENINGS: 

Never push objects of any kind into this product through the openings. If liquids have been spilled or 
objects have fallen into the device, unplug it immediately and have it checked by a qualified 
technician. 

Содержание Digi Scan 1600

Страница 1: ...ANALOG WAY SCAN 1600 DIGI SCAN 1600 EDITION 06 07 User s Manual MODEL DSV1600 MODEL SSV1600...

Страница 2: ...nplugged from wall outlet In both cases please follow these instructions The power cord of the device should be unplugged from the outlet when left unused for several days To unplug the device do not...

Страница 3: ...mais obstruer ses ouvertures Si un liquide ou un objet p n tre l int rieur de l appareil d branchez imm diatement l appareil et faites le contr ler par un personnel qualifi avant de le remettre en ser...

Страница 4: ...amos que lea cuidadosamente todas las consignas de seguridad y de funcionamiento del aparato antes de usarlo Conserve las instrucciones de seguridad y de funcionamiento para que pueda consultarlas pos...

Страница 5: ...ANEL DESCRIPTION 11 1 10 SCAN 1600 REAR PANEL DESCRIPTION 11 Chapter 2 STARTING 12 2 1 DIGI SCAN 1600 CONNECTIONS 12 2 2 SCAN 1600 CONNECTIONS 13 2 3 SETTINGS 13 2 4 IMAGE ADJUSTMENTS 13 Chapter 3 FRO...

Страница 6: ...devices DIGI SCAN 1600 connection diagram 2 6 3 4 5 5 RGB COMPONENT output connection SETTINGS c We recommend resetting the DIGI SCAN 1600 to all of its default values with the front panel display men...

Страница 7: ...input sources and then your display devices SCAN 1600 connection diagram 2 3 4 5 RGB COMPONENT output connection SETTINGS c We recommend resetting the SCAN 1600 to all of its default values with the...

Страница 8: ...2 meeting SMPTE 259 timing specifications Digi Scan 1600 comes with High performance Genlock to overlay graphics onto incoming Video with external switcher All of the Line Subcarrier phase parameters...

Страница 9: ...be downloaded from Analog Way website Scan 1600 is very easy to use and provides a high quality Video signal 1 5 DEVICES OPTIONS REFERENCES REFERENCE DESIGNATION DSV1600 DIGI SCAN 1600 SSV1600 SCAN 1...

Страница 10: ...ON ON OFF AC power switch O OFF I ON POWER Standard IEC connector 100 250 VAC 0 5A 50 60Hz automatic RS 232 RS 232 communication port on a DB9 female connector INPUT MONITOR COMPUTER INPUT Analog comp...

Страница 11: ...ng push FREEZE Freezes the displayed output short push 1 10 SCAN 1600 REAR PANEL DESCRIPTION RS 232 RS 232 communication port on a DB9 female connector INPUT MONITOR COMPUTER INPUT Analog computer inp...

Страница 12: ...s required connect a control monitor on the MONITOR OUT HD15 connector NOTE Set the RGB Hi Z 75 button on Hi Z if you connect a monitor on the MONITOR OUT connector If not set it on 75 NOTE The MONITO...

Страница 13: ...turn ON your input source and then your display devices SCAN 1600 connection diagram 2 3 4 5 RGB COMPONENT output connection 2 3 SETTINGS c We recommend resetting the device to all of its default val...

Страница 14: ...tton to enter in the CONTROL MODE From the CONTROL MODE press this button to confirm a selected item EXIT MENU button From the STATUS MODE press this button to enter in the CONTROL MODE From the CONTR...

Страница 15: ...4 5 6 7 1 NTSC 59 94 Hz 2 PAL 50 Hz 3 NTSC J 59 94 Hz 8 Preset 7 Zoom status 3 SOG input 4 H sync load 5 Genlock load 1 6 Genlock H ph 1 7 Genlock Sc ph 1 2 Output 1 Output status 2 Output std 3 Outp...

Страница 16: ...SV1600 only This function allows to adjust the genlock Subcarrier phase Adjust with ENTER 2 OUTPUT ENTER 2 1 Output status ENTER Displays the output status 2 2 Output std ENTER Select one of the follo...

Страница 17: ...ER Displays the image zoom status 3 8 Preset ENTER This function allows to set all the image parameters flicker filter Black level RGB level under overscan position size to the factory settings FUNCTI...

Страница 18: ...exe in Start Program ANALOGWAY SCAN1600 updater f In the Port menu select the Com port connected to the device g Click on START on the software h Press and hold the ENTER front panel button and simult...

Страница 19: ...D ROM into your drive the ANALOG WAY home window will open automatically e Select the language of the CD ROM menus then click on Install a Remote Control Software and select the name of your device IM...

Страница 20: ...OFTWARE continued SCAN 1600 DIGI SCAN 1600 PAGE 20 5 4 USING THE SOFTWARE c Click on the Input tab and select the Computer input type d Click on the Output tab and then select the needed adjustment ou...

Страница 21: ...1600 Chapter 5 REMOTE CONTROL SOFTWARE continued PAGE 21 5 4 USING THE SOFTWARE continued e Click on the Image tab and adjust your input f For the DSV1600 only click on the Genlock tab and make the g...

Страница 22: ...120 Hz 800 x 600 60Hz up to 120 Hz 1024 x 768 60Hz up to 120 Hz 1280 x 1024 60Hz up to 75 Hz 1600 x 1200 60Hz RB Reduced Blanking 6 2 VIDEO OUTPUTS RGB S VIDEO Connectors 4 BNC female Frequency 15 62...

Страница 23: ...NTSC Impedance 75 Ohm or Hi Z Output Passive loop through 6 4 REMOTE PORT Connector DB9 female Level RS 232 Data Rate 9600 bauds 8 bits data 1 bit stop no parity bit no flow control 6 5 ENVIRONMENTAL...

Страница 24: ...ni avant ni apr s Il n est pas n cessaire d appuyer sur ENTER du clavier Une commande peut tre pr c d e d une valeur voir chapitre A 2 STRUCTURE D UNE COMMANDE Lorsque l appareil re oit une commande...

Страница 25: ...no 1 yes l LOAD H sync load selection Rd Wr 0 1 0 Hi Z 1 75 ohms OUTPUT COMMANDS COMMANDES DE SORTIE F OFMT Output standard selection Rd Wr 0 2 0 NTSC 1 PAL 2 NTSCj GR REFR Synchronization mode select...

Страница 26: ...no sync detected 1 sync detected ih IHP Sign of the horizontal input sync Rd 0 1 0 negative 1 positive iv IVP Sign of the vertical input sync Rd 0 1 0 negative 1 positive ii IIN Interlaced signal det...

Страница 27: ...8 104 29 41 I 49 73 i 69 105 2A 42 J 4A 74 j 6A 106 2B 43 K 4B 75 k 6B 107 2C 44 L 4C 76 l 6C 108 2D 45 M 4D 77 m 6D 109 2E 46 N 4E 78 n 6E 110 2 F 47 O 4F 79 o 6F 111 0 30 48 P 50 80 p 70 112 1 31 49...

Страница 28: ...s including free materials and labor This warranty does not apply if the product has been improperly installed or abused handled with improper care used or stocked in abnormal conditions modified open...

Отзывы: