![Anaheim Automation DPD75601 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/anaheim-automation/dpd75601/dpd75601_user-manual_2939567045.webp)
45
#L010155
July 2004
Sample Program 3:
Sample Program 3:
Sample Program 3:
Sample Program 3:
Sample Program 3:
Sample Program 3 illustrates the setup and operation of the output on the fly function, and the use of the
if/then statement. The system is first homed using home type 0, waits for input 1 to be a value of 0
(grounded) and then is indexed 10,000 steps. During this index, output 1 needs to be turned on every
1000 steps 5 times starting at position 2000. At the end of the index, output 1 is then turned on again for
1 mS and the unit is then sent back the 10,000 steps to position 0, but the output should not be turned on.
The unit then repeats waiting for input 1 to be 0 and indexes again.