Installation and Setup
27
Instruction Manual – HDMI-UTPRO-0808
Installation Recommendations
Write the system’s serial number in an easily accessible location before installing the HDMI UTPro
in a rack.
The system’s serial number is located in two places on the enclosure: on the left rear and on the left side of
the enclosure near the power receptacle. The serial number also displays at the end of the product name in
NetLinx Studio’s ZeroConfig tree.
Use an earth-grounded power cord / system with the HDMI UTPro.
Attach all power cords to a single surge protector and/or an AC line conditioner.
Apply power to the HDMI UTPro enclosure before applying power to its source and destination devices.
Installation Procedure
A flow chart showing the installation sequence is in FIG. 9. The procedure on page 28 provides general steps with
references to detailed information found in later sections of the manual.
FIG. 9
Installation procedure
Caution:
To prevent overheating, avoid placing high heat producing equipment directly above or below
the enclosure or the Receivers. The enclosure requires a minimum of one empty rack unit above and below
(three empty rack units are recommended). Stacking Receivers will not allow the units adequate cooling.
If mounting in a rack using some type of tray, a minimum of one empty rack unit above and below is
recommended. Verify that the openings on the sides of the enclosure and the front and back of the
Receivers are not blocked and do not have restricted air flow.