Appendix B – Telnet (Terminal) Commands
111
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Telnet Commands (continued)
SEND_COMMAND
[D:P:S,"'command'"]
Sends the specified SEND_COMMAND (does not work with queries) to the current DXLink
Transmitter or Receiver.
Note:
P
(Port) number must be 1;
S
(System) number must be 0 (zero).
Note:
Commands cannot be forwarded to other D:P:S. Asynchronous notifications are
available for the Transmitters via Telnet (and NetLinx Studio).
Example:
send_command 6501:1:0,"’VIDIN_AUTO_SELECT-ENABLE’"
EXIT
Exit the Telnet session
FACTORYFWIMAGE
Resets unit to factory firmware image and reboots DXLink Transmitter or Receiver.
GET CONFIG
Displays the current connection settings.
Example:
>get config
Device number: 7010
Connection Settings
--------------------------------
Mode: NDP
System Number: 2155
Master IP/URL: 192.168.43.83
Master Port: 1319
Username:
Password:
IP Settings
--------------------------------
HostName: DXL-RX-36d0110
Type: DHCP
IP Address: 192.168.43.63
Subnet Mask: 255.255.255.0
Gateway IP: 192.168.43.2
MAC Address: 00:60:9f:99:26:f1
DHCP Server : 192.168.43.2
Lease Origin : THU 01/09/2031 12:59:02
Lease Duration : SUN 01/12/2031 12:59:02 (259200 sec)
Lease Renew (T1): SAT 01/11/2031 00:59:02 (129600 sec)
Lease Rebind (T2): SUN 01/12/2031 03:59:02 (226800 sec
DNS Servers
--------------------------------
Domain suffix: amx.internal
Entry 1: 192.168.40.7
Entry 2: 192.168.40.8
Note:
The system number and IP addressing information displayed is reflective of actual
operating values, not stored parameters.
GET CONNECTION
Shows the Master connection information.
Example:
>get connection
Connection Settings
------------------------------
Mode: UDP URL
System Number: 1
Master IP/URL: 192.168.44.53
Master Port: 1319
Username:
Password:
GET DEVICE
Displays the device number.