5
Fig. 30
Fig. 31B
Fig. 31A
Fig. 32
Fig. 26
Fig. 28
a
b
*
*
*
*
c
e
d
g
f
Fig. 29
Fig. 27
BELOW COUNTER NON-eSpring
®
FAUCET INSTALLATION (11-0720-CA)
REVIEW ALL INSTRUCTIONS IN THE PURCHASED NON-eSpring FAUCET OR DISPENSING
DEVICE TO BE SURE YOU HAVE ALL PARTS AND TOOLS PRIOR TO INSTALLATION.
1. Install Auxiliary Faucet or Dispensing Device according to manufacturer’s
instructions.
2. Follow preparation steps for any faucet or dispensing device on p. 3.
3. Review bag labeled CXV3645,
which contains components used
with NON-
eSpring
installations (Fig.
26).
a. Supply Connector
b. Pressure Regulator
c. Inlet Tubing
d. Outlet Tubing
e. Tubing Removal Tool
f. T Connector
g. Tubing Reducer Connector
* Faucet not included
4. a)
Lay
the red tube from the Pressure Regulator Assembly on the top of the
diagram, and lay the blue tube on the bottom. Use a pen to
mark
them at
the arrows (Fig. 27). (These ends will connect to the Water Purifier).
b)
Lay
the unmarked end of the blue tubing on the top of the diagram and
mark
a line at ¾” (18 mm). (Fig. 27).
c)
Lay
the tube from the cold water supply on the top of the diagram and
mark
a line at ¾” (18mm) or at arrow (Fig. 27).
5.
Remove
the Top Shroud from the Water
Purifier
. Remove the Electronic
Module
(Fig. 28).
6. Connect the tube from the cold water
supply to the screen side of the Supply
Connector on Pressure Regulator Assembly
. Arrow in balloon shows water flow
direction
(Fig. 29).
NOTE: The supplied components (Fig. 29) must be
used between the valve at the water supply and
the eSpring Water Purifier.
7.
Insert
the RED tube from the Pressure
Regulator Assembly into the large port
on the Bracket.
Insert
the end of the
BLUE tube marked at 5/8” (15 mm) into
the small port on the Bracket (Fig. 30).
NOTE: You will feel resistance before the
tubes are fully installed. Ensure the tube is
fully pushed in until it meets the mark or the
marks disappear, as a check on each of the
tube connections in steps 7 and 8.
8. The other end of the BLUE tube
marked at ¾” (18mm) connects to
the NON-
eSpring
Faucet or dispensing
device by inserting BLUE tube into
the Tubing Reducer Connector. Follow
manufacturer’s installation instructions
to connect the other end of the
connector to the faucet or dispensing
device (Fig. 31A).
NOTE: For installation with refrigerator
or secondary device use the T Connector
in place of the Tubing Reducer Connector
(Fig 31B).
9.
Open
the NON-
eSpring
Faucet or dispensing device
.
Open
the water
supply shut-off valve
to start water flowing through the Water Treatment
System (Fig. 32).
NOTE: It will take a short time for water to saturate the Cartridge and flow
from the Faucet. Flush for a minimum of 5 U.S. gallons (20 liters) (approximately
5-15 minutes) to remove air pockets and carbon dust. If water is not clear,
see Troubleshooting, p. 8.
10. Turn off the NON-
eSpring
Faucet or dispensing device and check for any
signs of leakage at all tubing connections
(Fig. 32). If there is leaking or
bubbling, refer to Troubleshooting, p. 7.
NOTE: During use periodically check system for leaks.
11.
Skip to COMPLETING THE INSTALLATION, p. 10.
1035795_eng.indd 5
6/10/14 4:56 PM