10
Fig. 46
Fig. 43
Fig. 47
Fig. 48
Fig. 49
Fig. 50
Fig. 44
Fig. 45A
Fig. 45B
13.
Screw
on the Retaining Ring until it hits
a STOP. No exposed threads should
be visible below the Retaining Ring. If
threads are exposed, the Bracket is not
pushed all the way down (Fig. 43).
NOTE: The Retaining Ring is not meant to
create a water seal, so Do Not rotate past
the STOP, as this may result in Carton Water
Treatment System damage.
14.
Reinsert each tube
into the proper
locations on the Bracket.
Insert
tubes
until they meet the marks or the marks
disappear (Fig. 44).
NOTE: You will feel resistance before the tube
is fully installed.
15. Turning on the cold water to the Water Purifier.
a) For the Existing Faucet:
Turn on
the cold water at
the faucet
and
pull
the Diverter pin
(Fig. 45A).
b) For the Auxiliary Faucet:
With the Auxiliary Faucet
handle still in the open
position
,
open
the
supply shut-off valve
(Fig. 45B).
NOTE: It will take a short time for
water to saturate the Cartridge
and flow from the Diverter or
Faucet. Flush for 5 minutes
[approximately 5 U.S. gallons (20 liters)] to remove air pockets and carbon dust. If
water is not clear, see Troubleshooting, p. 8.
16.
Check
for any signs of leakage (Fig. 46).
Refer to Troubleshooting, p. 7.
NOTE: During use periodically check system
for leaks.
17.
Turn off
the water to the Water Purifier.
COMPLETING THE
INSTALLATION
1.
Replace
the Electronic Module
.
Store
the Tubing Removal Tool for future
use
(Fig. 47).
2.
Push
cord strain relief into notch on
Base. Make sure the tubes are in the
notches on the back of the Base
(Fig. 48).
3.
Place
the Top Shroud onto Base
.
Plug
the Power Adapter into the wall
outlet
(Fig. 49)
4.
Wait
for monitor to signal new Cartridge
with a beep. This may
take 30 seconds.
5.
Turn on
water
to the Water Purifier and
make sure that the display has a
blue cup
with rolling water drops,
p. 6 (Fig. 50).
If not, refer to Troubleshooting, p. 8.
1035795_eng.indd 10
6/10/14 4:56 PM