CARTRIDGE REPLACEMENT
(10-0186)
Refer to the exploded view of the
eSpring
®
Water Purifier for assistance
with part names (See inside front cover).
1. Unplug the Power Adapter from the
wall outlet.
2.
Turn off
water to Water Purifier.
a) If using the Diverter,
turn off
the
kitchen faucet and place the Water
Purifier in the sink. Pull the metal
pin on the Diverter to drain water
(Fig. 33A).
b) If using the Auxiliary Faucet,
turn off
the cold water supply using the shut-off
valve
. Turn on Faucet to drain water and
leave open
. Place towels
around the Base of the Water Purifier (Fig. 33B).
3.
Remove
the Top Shroud
. Remove
the Electronic Module
. Then,
remove the tubing removal tool
(Fig. 34).
4.
Draw
a line with an ink pen across the
top of each tube where it meets the
rings on the Water Purifier (Fig. 35).
5.
Make sure
the logo on the removal
tool is facing out and the tool is flat
against the Bracket.
Firmly push
the tool against the rings with your
fingers and then pull the tubes out
with the opposite hand while rings are
depressed (Fig. 36).
NOTE: If you do not have the Removal Tool,
remove each tube by pressing evenly with
your fingertips on both sides of the rings
that surround the tubing. Then, pull the
tube out with the opposite hand.
6.
Unscrew
to remove the Retaining Ring
(Fig. 37).
7.
Lift the handle
on the Bracket.
Pull straight
up
to remove the attached used Cartridge
and Bracket (Fig. 38).
8.
Unscrew
Cartridge from Bracket to remove
and
dispose
of the Cartridge in accordance
with local requirements (Fig. 39).
NOTE: The UV lamp in the Cartridge contains
mercury. Please dispose of according to local,
state or federal laws.
9. Empty water from the Base. Then,
inspect
seal and upper interior surface of Base and
remove
any dirt (Fig. 40).
NOTE: DO NOT allow vegetable oil, petroleum jelly,
or other lubricants, solvents, ammonia, alcohols,
acids, or strong cleaning solutions to come into
contact with the Water Purifier. They could
cause permanent damage to the Base. Use food
grade silicone (WTI-0895) on o-rings to lubricate
if needed. When cleaning, use a mild liquid
dishwashing detergent and water.
10.
Remove
the protective plastic wrap from
the new
eSpring
Cartridge (10-0186).
11.
Firmly press
Cartridge and Bracket together
.
Screw
the Cartridge onto the Bracket
until it comes to a STOP
(Fig. 41).
12.
Reinsert
the Bracket (with the attached
Cartridge) into the base by
aligning the
notches
of the Bracket with the tabs on the
Base
. With the handle down,
firmly
push down
on the Bracket until it contacts
the Base
(Fig. 42).
1035795_eng.indd 9
6/10/14 4:56 PM